Difference between revisions of "DC hits to Moller XSection"
Line 56: | Line 56: | ||
For a hit at layer 1, wire 2 we find the corresponding angle theta in the lab frame to be 5.19 degrees | For a hit at layer 1, wire 2 we find the corresponding angle theta in the lab frame to be 5.19 degrees | ||
− | < | + | <center>[[File:Layer1Wire2.png]]</center> |
Finding the difference between the two wires, | Finding the difference between the two wires, | ||
− | <center><math>5.19-4.91=.28\ degrees \frac{\pi\ radians}{180^{\circ}}=.004886921906\approx .005 radians</math></center> | + | <center><math>5.19-4.91=.28\ degrees \frac{\pi\ radians}{180^{\circ}}=0.004886921906\approx\ 0.005\ radians</math></center> |
Revision as of 21:09, 25 October 2016
Verification using LUND and evio files
Examing the CM Frame Theta angles which correspond to Lab frame angles within 5-40 degrees, for only on degree in Phi (0 degrees)
For each degree in Theta in the Lab frame, the correct kinematic variables are written to a LUND file 1000 times. These events are read from the evio file using
The Moller Scattering angle Theta is read from the evio file, and it's weight adjusted by dividing by the number it was multiplied by (1000) to give
From the evio file, a histogram can be constructed that will only record the Moller events which result in hits in the drift chamber. A hit for this setting is the
Plotting the Moller scattering angle Theta in the Center of Mass frame, and adjusting the weight by the number of times the specific angle caused hits. We should recover the Moller differential cross-section as found previously.
Once the validity of the Moller differential cross-section is established, we can transform from the center of mass to the lab frame as shown earlier. Since the detector is in the lab frame, the hits collected will have to be used to compose a histogram for the Moller scattering angle in the lab frame. We can show that the Moller events that register as hits in the lab matches the Moller differential cross-section in the lab.
Determining wire-theta correspondance
To associate the hits with the Moller scattering angle theta, the occupancy plots of the drift chamber hits by means of wire numbers and layer must be translated using the physical constraints of the detector. Using the data released for the DC:
DC: Drift Chambers(specs)
This gives the detector with a working range of 5 to 40 degrees in Theta for the lab frame, with a resolution of 1m radian.
This sets the lower limit:
This sets the upper limit:
Taking the difference,
Dividing by 112, we find
CED Verification
Using CED to verify the angle and wire correlation,
For a hit at layer 1, wire 1 we find the corresponding angle theta in the lab frame to be 4.91 degrees
For a hit at layer 1, wire 2 we find the corresponding angle theta in the lab frame to be 5.19 degrees
Finding the difference between the two wires,