Overview
A series of triggered CF-252 runs are conducted while varying detector PMT high voltage and threshold.
results
| Detector | rate | noise | run # | PMT threshold | HV | 
|---|---|---|---|---|---|
| D30 | ? | ?? | r5242 | 25 | 1700 | 
| D90 | ? | ?? | |||
| D150 | ? | ?? | |||
| D225 | ? | ?? | |||
| D30 | ? | ?? | r5239 | 30 | |
| D90 | ? | ?? | |||
| D150 | ? | ?? | |||
| D225 | ? | ?? | |||
| D30 | ? | ?? | r5240 | 35 | |
| D90 | ? | ?? | |||
| D150 | ? | ?? | |||
| D225 | ? | ?? | |||
| D30 | ? | ?? | r5241 | 40 | |
| D90 | ? | ?? | |||
| D150 | ? | ?? | |||
| D225 | ? | ?? | |||
| D30 | ? | ?? | r5243 | 25 | 1650 | 
| D90 | ? | ?? | |||
| D150 | ? | ?? | |||
| D225 | ? | ?? | |||
| D30 | ? | ?? | r5244 | 30 | |
| D90 | ? | ?? | |||
| D150 | ? | ?? | |||
| D225 | ? | ?? | |||
| D30 | ? | ?? | r5245 | 35 | |
| D90 | ? | ?? | |||
| D150 | ? | ?? | |||
| D225 | ? | ?? | |||
| D30 | ? | ?? | r5246 | 40 | |
| D90 | ? | ?? | |||
| D150 | ? | ?? | |||
| D225 | ? | ?? | |||
| D30 | ? | ?? | r5247 | 25 | 1600 | 
| D90 | ? | ?? | |||
| D150 | ? | ?? | |||
| D225 | ? | ?? |