7/16/16

PMT top and bottom is in coincidence with a trigger placed 3" below the CF-252 source.

PMT pulses are widened to 500 ns in electronics in order to avoid double counting.


Discriminator thresholds:

Trigger: 15 mv

PMT's: 60 mv


Detector Count rate at -1700 V (Hz) Difference
angle color Source in Source out
30 Red 8.3 4.8 3.5
90 Yellow 2.4 0.6 1.8
150 Blue 3.7 1.67 2.0