Difference between revisions of "Niowave 6-2016"
Jump to navigation
Jump to search
Line 23: | Line 23: | ||
|0.0 ||6 || 18 | |0.0 ||6 || 18 | ||
|- | |- | ||
− | |0.0 || 8 ||50,43,42,39,43 | + | |0.0 || 8 ||50,43,42,39,43= 43<math> \pm</math> 4 |
|- | |- | ||
|0.0 || 10 || 122,112,119,95,117 = 113<math> \pm</math> 11 | |0.0 || 10 || 122,112,119,95,117 = 113<math> \pm</math> 11 | ||
Line 34: | Line 34: | ||
|- | |- | ||
| 0.3 || 6 || 89 | | 0.3 || 6 || 89 | ||
+ | - | ||
+ | | 0.3 || 8 || running now | ||
|- | |- | ||
| 0.3 || 10 || 664,652,618,591,603=626<math> \pm</math> 31 | | 0.3 || 10 || 664,652,618,591,603=626<math> \pm</math> 31 |
Revision as of 13:31, 15 June 2016
Previously observed in Niowave_1-2016
34.8 mm pipe, 0.0 -> 0.5 Tesla, E= 6,8,10 MeV.
positrons produced per million incident electrons on a 2mm thick PbBi target that exit a 15 cm long Solenoid surrounding a 34.8 mm diameter beam pipe.
running in
/home/foretony/src/GEANT4/geant4.9.6.p02/Simulations/NioWave/SolenoidExit/batch/
Solenoid Field (Tesla) | Incident Electron Energy (MeV) | Positrons/Million electrons | |||
0.0 | 6 | 18 | |||
0.0 | 8 | 50,43,42,39,43= 43 | 4|||
0.0 | 10 | 122,112,119,95,117 = 113 | 11|||
0.2 | 6 | 65,62,71,62,58=64 | 5|||
0.2 | 8 | 233,210,218,213,215 =218 | 9|||
0.2 | 10 | 404,418,420,420,416=416 | 7|||
0.3 | 6 | 89
- |
0.3 | 8 | running now |
0.3 | 10 | 664,652,618,591,603=626 | 31