Difference between revisions of "Niowave Report 11-30-2015"
Jump to navigation
Jump to search
Line 7: | Line 7: | ||
==Optimal Thickness== | ==Optimal Thickness== | ||
+ | |||
+ | 2mm thick PbBi, 10 MeV, 1 cm cylindrical incident electron distribution | ||
+ | |||
+ | G4beamline pencil beam 10 cm radius | ||
+ | <pre> | ||
+ | beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \ | ||
+ | sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \ | ||
+ | meanMomentum=10. sigmaE=0. maxR=10. | ||
+ | </pre> | ||
+ | |||
+ | Incident Electron spatial distribution and energy | ||
+ | |||
+ | [[File:PbBi_5-1-15_X-Yposition.png | 200 px]][[File:PbBi_5-1-15_Ein.png | 200 px]] | ||
+ | |||
+ | Positron and Electron Momentum after the converter | ||
+ | |||
+ | [[File:PbBi_5-1-15_Ppositron.png | 200 px]][[File:PbBi_5-1-15_Pelectron.png | 200 px]] | ||
+ | |||
+ | |||
+ | [[File:G4Bl-vs-MCNPX_5-5-2015.png| 200 px]] | ||
==Optimal Solenoidal Field== | ==Optimal Solenoidal Field== |
Revision as of 19:15, 28 November 2015
Overview
10 MeV electron beam
3.48 cm diameter beam pipe
Target optimization
Optimal Thickness
2mm thick PbBi, 10 MeV, 1 cm cylindrical incident electron distribution
G4beamline pencil beam 10 cm radius
beam ellipse particle=e- nEvents=1000000 beamZ=0.0 beamX=0. beamY=0. \ sigmaX=10.0 sigmaY=10.0 sigmaXp=0.000 sigmaYp=0.000 \ meanMomentum=10. sigmaE=0. maxR=10.
Incident Electron spatial distribution and energy
Positron and Electron Momentum after the converter
Optimal Solenoidal Field
Beam Pipe heating
The energy deposited by electrons scattered into a 3.48 diameter stainless steel beam pipe (1.65 mm thick) from a PbBi target as a function of a uniform Solenoidal magnetic field.
The histogram is binned in 100 (10 cm) bin widths. The surface area becomes
To convert From Mev/ e- to kW/cm^2 assuming a current of 1mA (10^-3 C/s) you
Solenoid Description
A 10 MeV electron beam with a radius of 0.5 cm was incident on a 2 mm thick PbBi target. The target is positioned at Z = -901 mm.