Difference between revisions of "Niowave Report 11-30-2015"
Jump to navigation
Jump to search
Line 1: | Line 1: | ||
+ | =Overview= | ||
+ | |||
+ | 10 MeV electron beam | ||
+ | |||
+ | 3.48 cm diameter beam pipe | ||
=Target optimization= | =Target optimization= | ||
Revision as of 00:15, 28 November 2015
Overview
10 MeV electron beam
3.48 cm diameter beam pipe
Target optimization
Optimal Thickness
Optimal Solenoidal Field
Beam Pipe heating
The energy deposited by electrons scattered into a 3.48 diameter stainless steel beam pipe (1.65 mm thick) from a PbBi target as a function of a uniform Solenoidal magnetic field.
The histogram is binned in 100 (10 cm) bin widths. The surface area becomes
To convert From Mev/ e- to kW/cm^2 assuming a current of 1mA (10^-3 C/s) you
Solenoid Description
A 10 MeV electron beam with a radius of 0.5 cm was incident on a 2 mm thick PbBi target. The target is positioned at Z = -901 mm.