Revision as of 15:52, 28 April 2015
Development of a Positron source using a PbBi converter and a Solenoid
Converter target properties
Definition of Lead Bismuth
1cm diameter target
2 mm thick PbBi
0.5 Tesla solenoid
G4BeamLine
Target thickness optimization
First simple test is to send 1 million, 10 MeV electrons towards a PbBi target and count how many positrons leave the downstream side
PbBi Thickness (mm) | #positrons/million electrons |
1 | 960 |
2 | 1963 |
3 | 2233 |
4 | 2184 |
5 | 2042 |
6 | 1851 |