Difference between revisions of "04-20-2015"

From New IAC Wiki
Jump to navigation Jump to search
Line 2: Line 2:
  
 
=Fake stop time=
 
=Fake stop time=
 +
Discriminator width was decreased from 40 ns to
 +
 +
Discrimniator threshold is set to 100 mv
 +
 +
The delay for the fake stop is set to 800 ns
  
Found some double pulsing out of the discriminator that was 100 ns later in time causing a second peak other than the expected one at 400 ns.
 
  
Below is a picture of a double pulse
 
  
 
[[File:FakeStop_4-20-2015_A.png| 200 px]]
 
[[File:FakeStop_4-20-2015_A.png| 200 px]]

Revision as of 17:34, 20 April 2015

Started testing detector 4 again.

Fake stop time

Discriminator width was decreased from 40 ns to

Discrimniator threshold is set to 100 mv

The delay for the fake stop is set to 800 ns


FakeStop 4-20-2015 A.png

Below is a picture of the typical 400 ns fake stop pulse that should appear as a second hit in the Multihit TDC.


FakeStop 4-20-2015 B.png


CODA/CODAreader/ROOT_V5.30/R1DC/evio2nt -fr4516.dat > /dev/null


R1DC->Draw("(evt.TDC1190[1][6]-evt.TDC1190[2][6])/10>>(4096,-4096,4096)");

Run 4534

R4534FakeStop C.png

Now increase delay of fake stop to 800 ns

200 px

Terminator test

r4534

Terminators in

Discriminator at 20 mv

PMT detector #4 HV at -1000 Volts


2nCor_44#Run_Plan