Difference between revisions of "Simulations of Particle Interactions with Matter"
Line 65: | Line 65: | ||
Silicon detectors and Ionization chambers are two commonly used devices for detecting radiation. | Silicon detectors and Ionization chambers are two commonly used devices for detecting radiation. | ||
+ | |||
+ | approximately 1 eV of energy is all that you need to create an electron-ion pair in Silicon | ||
+ | |||
+ | <math>P(E=1 eV) = e^{-5/0.0258} \approx 10^{-85}</math> | ||
=== The Monte Carlo method === | === The Monte Carlo method === |
Revision as of 17:09, 31 August 2007
Overview
Particle Detection
A device detects a particle only after the particle transfers energy to the device.
Energy intrinsic to a device depends on the material used in a device
Some device of material with an average atomic number (
) is at some temperature ( ). The materials atoms are in constant thermal motion (unless T = zero degrees Klevin).Statistical Thermodynamics tells us that the canonical energy distribution of the atoms is given by the Maxwell-Boltzmann statistics such that
represents the probability of any atom in the system having an energy where
Note: You may be more familiar with the Maxwell-Boltzmann distribution in the form
where
would represent the molesules in the gas sample with speeds between andExample 1: P(E=5 eV)
What is the probability that an atom in a 12.011 gram block of carbon would have and energy of 5 eV?
First lets check that the probability distribution is Normailized; ie: does
?
is calculated by integrating P(E) over some energy interval ( ie: ). I will arbitrarily choose 4.9 eV to 5.1 eV as a starting point.
assuming a room empterature of
then
and
or in other words the precise mathematical calculation of the probability may be approximated by just using the distribution function alone
This approximation breaks down as
Since we have 12.011 grams of carbon and 1 mole of carbon = 12.011 g =
carbon atomsWe do not expect to see a 5 eV carbon atom in a sample size of
carbon atoms when the probability of observing such an atom isThe energy we expect to see would be calculated by
If you used this block of carbon as a detector you would easily notice an event in which a carbon atom absorbed 5 eV of energy as compared to the energy of a typical atom in the carbon block.
Silicon detectors and Ionization chambers are two commonly used devices for detecting radiation.
approximately 1 eV of energy is all that you need to create an electron-ion pair in Silicon