| | 6603|| added attenuator, changed CFD post amp no longer differentiating signal, Shutter '''Closed''' V_gem= 2800 V_cath=3100, 10 Hz clock in scaler channel 5, rate was 114 Hz, | | | 6603|| added attenuator, changed CFD post amp no longer differentiating signal, Shutter '''Closed''' V_gem= 2800 V_cath=3100, 10 Hz clock in scaler channel 5, rate was 114 Hz, |
| | |- |
| | | 6605|| added attenuator, switch the CFD to LED,post amp no longer differentiating signal, Shutter '''Closed''' V_gem= 2800 V_cath=3100, 10 Hz clock in scaler channel 5, rate was 26 Hz, |
| |- | | |- |
| |} | | |} |
Revision as of 19:15, 8 November 2013
Runlist
| Run |
Conditions
|
| 6588 |
Run GEM detector in Hall at V_gem= 2650 V_cath=2950 Shutter Open! Signal on ADC5 at about 1000 channels, CFD threshold at 84 mV, 10 Hz clock in scaler channel 5, rate was 7 Hz
|
| 6589 |
same as run 6588 except, V_gem = V_cath = 2650 and lowered CFD threshold to 64 mV because there were no triggers, rate was 2 kHz, noise was at 1000 channels as well, a lot of pileup but histogram seems representative of noise. increase GEM gain
|
| 6593 |
Run GEM detector in Hall at V_gem= 2700 V_cath=3150, CFD threshold at 88 mV, 10 Hz clock in scaler channel 5, rate was 27 Hz, 
|
| 6594 |
V_gem= 2750 V_cath=3150, CFD threshold at 88 mV, 10 Hz clock in scaler channel 5, rate was 27 Hz,
|
| 6595 |
Shutter Closed now V_gem= 2750 V_cath=3150, CFD threshold at 88 mV, 10 Hz clock in scaler channel 5, rate was 27 Hz, 33 min 29 sec,
|
| 6596 |
Shutter Open now V_gem= 2800 V_cath=3100, CFD threshold at 88 mV, 10 Hz clock in scaler channel 5, rate was 31 Hz,
|
| 6597 |
Shutter Closed now V_gem= 2800 V_cath=3100, CFD threshold at 88 mV, 10 Hz clock in scaler channel 5, rate was 27 Hz,
|
| 6598 |
Decreased Post amp from x6 to x1 Shutter Closed V_gem= 2800 V_cath=3100, CFD threshold at 21 mV, 10 Hz clock in scaler channel 5, rate was 22 Hz,
|
| 6599 |
same as run 6598 V_gem= 2800 V_cath=2800, CFD threshold at 21 mV, rate was 79 Hz,
|
| 6600 |
Decreased Post amp from x6 to x1 Shutter Closed V_gem= 2800 V_cath=3100, CFD threshold at 15 mV, 10 Hz clock in scaler channel 5, rate was 79 Hz,
|
| 6601 |
Decreased Post amp from x6 to x1 Shutter Open V_gem= 2800 V_cath=3100, CFD threshold at 15 mV, 10 Hz clock in scaler channel 5, rate was 114 Hz,
|
| 6603 |
added attenuator, changed CFD post amp no longer differentiating signal, Shutter Closed V_gem= 2800 V_cath=3100, 10 Hz clock in scaler channel 5, rate was 114 Hz,
|
| 6605 |
added attenuator, switch the CFD to LED,post amp no longer differentiating signal, Shutter Closed V_gem= 2800 V_cath=3100, 10 Hz clock in scaler channel 5, rate was 26 Hz,
|
TGEMS#GEM_fission_chamber_tests