Difference between revisions of "Detector Description"

From New IAC Wiki
Jump to navigation Jump to search
Line 29: Line 29:
 
[[File:Charge_collector.jpg  | thumb |alt=Example alt text|Fig. shows the charge collector wire's dimensions and arrangement.| center| 200px]]
 
[[File:Charge_collector.jpg  | thumb |alt=Example alt text|Fig. shows the charge collector wire's dimensions and arrangement.| center| 200px]]
  
 
+
All the previous components exist in a sealed chamber that consists of two ertalyte plastic sheets; they are bolted together by a number of M3 plastic screws located around the detector window to form a well enclosed cavity. Also, the chamber has a 13x13cm kipton window for incident particles.The figures below show top, bottom and side view of the detector's chamber design.
 
 
4- A sealed chamber; All the previous components exist in a chamber that consists of two ertalyte plastic sheets which are bolted together by a number of M3 plastic screws located around the detector window to form a well enclosed cavity. Also, the chamber has a 13x13cm window for incident particles.
 
 
 
 
 
 
 
The figures below show top, bottom and side view of the detector design.
 
  
  

Revision as of 13:33, 25 October 2013

GEM Detector Design

You should first describe the basics of the gas electron multiplier  then describe the ionization chamber equiped with GEM foils, then describe the assembly in a clean room environment.


Clean Environment

Gaseous detectors, like most detectors, are constructed in environments that minimize the presence of contaminants. Most of the methods for detector construction and maintenance demand a clean environment. Generally, clean environments are classified depending on the size and the number of existing particulates in the room; each class maintains its environment by filtering the air that enters the room, by keeping air circulation in a specific rate, and by using soft or hard walls that isolate the room from the surrounding environment. Clean rooms have restrictions on the type of materials for the equipment and furniture, and have special instructions for the workers who can carry contaminants: the workers have to use gloves, hats, pants, shoes, and gowns that are designed for this purpose. Laminar hoods are another method to get a clean environment: they are easy to maintain, have less restrictions to keep them clean,and usually provide enough space for building and maintaining small size detectors.

Detector Structure

You should describe the features of the detector using a paragraph and not an enumerated list.
 First start with a description of the GEM foil and how the strong electric fields cause secondary ionization
After that you describe using several of the foils to further multiply the signal and introduce the anode and cathode to direct ionized electrons through the three amplification stages.
 Finally you can describe the HV network used to supply a voltage to all the components and the ionization chamber which immerses them in the Ar/Co2 gas.

The triple GEM detector is based on three GEM preamplifiers, a cathode and an anode. The GEM preamplifier is made of a copper-clad kipton plate which is 50 um thick and has an area of 10x10cm, it has holes that are chemically etched with a diameter of 50 um; and has a 10um rim. The holes have a an equilateral triangular pattern with a 140 um pitch distance. In case of the triple GEM detector; the detector possesses three GEM cards in square plastic frames, they are placed parallel to the cathode and are separated by vertical distance of 2.8 mm as shown in the figure below.

Example alt text
Fig.1 shows the original GEM detector design.

The cathode is a square copper plate that is a 10x10cm and has a distance of 3.5 mm from the top of the first GEM card. This cathode design allows a rise in potential on its surface up to 5 kV (in the air) without any discharge effect.The charge collector (readout anode) is constructed of 50-80 micron wide strips and are insulated to determine the location of the collected electrons. They are arranged to give equal charge sharing on the charge collector.


Example alt text
Fig. shows the charge collector wire's dimensions and arrangement.

All the previous components exist in a sealed chamber that consists of two ertalyte plastic sheets; they are bolted together by a number of M3 plastic screws located around the detector window to form a well enclosed cavity. Also, the chamber has a 13x13cm kipton window for incident particles.The figures below show top, bottom and side view of the detector's chamber design.


GEM top.png GEM bottom.png GEM sides.png

Modifying the GEM detector as neutron sensitive detector

The GEM’s original design was modified to convert it to a neutron sensitive detector. The cathode design has a 3 cm diameter coating, and 40-50 um thickness. The kepton window had an increase in height of 2.5 mm, which helped to increase the distance of the cathode to 8 mm from the top of the first of GEM card (instead of 3.5 mm in the original design). An FR4 shutter was attached in the space between the cathode and the first GEM card, which had enough area to cover the coating area; it has a position controller that helps to open and close the shutter. When the shutter is closed, it covers the U-233 coating and stops the emitted fission fragments from causing ionization in the gas, but when the shutter is open, the ionization of the fission fragments produces a signal that indicates the existence of neutrons inside the chamber which the detector trigger detects for analysis by the DAQ system.



The figures below show the modified components of the detector.

Example alt text
Adding modifications to GEM design.
Example alt text
Modifying the cavity size by the increasing the height of kapton window.
Example alt text
Detector's shutter is open.
Example alt text
Detector's shutter is close.

High voltage divider

GEM preamplifiers are connected with high voltage divider circuit. as shown in the figure below:

GEM HV Dist Net.jpg


The circuit provides the cathode with a voltage of 3.6 kV, and it produces an electric field which drifts most of the electrons that are primarily produced by ionization. The circuit also provides the GEM preamplifiers with voltage between the top and bottom of each card; the voltage gradually decreases to have the least value between the sides of the third GEM card. This design's advantage is to provide enough voltage for electron multiplication, and to guide most of the drift electrons to the grounded readout plate.

The following table shows the voltage measurements between the sides of the GEM preamplifiers, and voltage between each side and the ground using the HV-voltage divider circuit shown in figure (2).

[math] V_{source} \pm 1 [/math] [math] V_{G1T} \pm 1 [/math] [math] V_{G1B} \pm 1 [/math] [math] \Delta V_1 \pm 1 [/math] [math] V_{G2T} \pm 1 [/math] [math] V_{G2B} \pm 1 [/math] [math] \Delta V_2 \pm 1[/math] [math] V_{G3T} \pm 1 [/math] [math] V_{G3B} \pm 1 [/math] [math] \Delta V_3 \pm 1 [/math]
2550 2579 2259 304 1671 1394 279 818 570 245
2600 2630 2303 310 1704 1421 285 834 581 250
2650 2680 2348 316 1737 1449 290 850 592 255
2700 2731 2393 322 1770 1476 296 866 603 260
2750 2781 2373 328 1803 1503 302 882 614 264
2800 2832 2482 332 1836 1530 307 898 625 269


Go Back [1]