Difference between revisions of "PosRun 10 14 2013"
Jump to navigation
Jump to search
Line 68: | Line 68: | ||
===Shielded Cell direct beam with magnet=== | ===Shielded Cell direct beam with magnet=== | ||
− | reconfigure with magnet in shielded cell to deflect charged particles towards NaI detector #3, | + | reconfigure with sweep magnet in shielded cell to deflect charged particles towards NaI detector #3, |
{| border="1" |cellpadding="20" cellspacing="0 | {| border="1" |cellpadding="20" cellspacing="0 | ||
Line 86: | Line 86: | ||
| 6517 || 2 min 18 s ( pulses) || same as last run except: Magnet is out | | 6517 || 2 min 18 s ( pulses) || same as last run except: Magnet is out | ||
|- | |- | ||
− | | 6518 || 7 min 10s ( pulses) || same as last run except: positron dipoles set to 8 MeV, Magnet is out | + | | 6518 || 7 min 10s ( pulses) || same as last run except: positron dipoles set to 8 MeV, sweep Magnet is out |
|- | |- | ||
− | | 6519 || min s ( pulses) || same as last run except: Magnet is In positron bending mode | + | | 6519 || min s ( pulses) || same as last run except: sweep Magnet is In positron bending mode |
+ | |- | ||
+ | | 6520 || min s ( pulses) || same as last run except: sweep Magnet is In electron bending mode | ||
|} | |} | ||
Revision as of 23:13, 14 October 2013
Run list
Scaler channel #2 counts the number of beam pulses
Detector 4 is Beam Left and in ADC channel 7, Ortec Dual Spec amp set to course=10, fine=39, Canberra CFD set to 85 mV lower threshold
Detector 1 is Beam Right and in ADC channel 3, Ortec Dual Spec amp set to course=20, fine=10, Canberra CFD set to 70 mV lower threshold
In-flight
40 MeV on Tungsten
40 MeV electrons are hitting the positron production Tungsten target
Shielded Cell direct beam with magnet
reconfigure with sweep magnet in shielded cell to deflect charged particles towards NaI detector #3,
6511 | min s ( pulses) | dipoles in electron mode transporting 8 MeV, NaI at -700 Volts |
6512 | min s ( pulses) | dipoles in electron mode transporting 6 MeV, Magnet is OUT |
6513 | min s ( pulses) | dipoles in electron mode transporting 6 MeV, Magnet is IN and deflecting positrons towards NaI |
6514 | 12 min 3 s ( pulses) | same as last run except: dipoles in positron mode, doubled current from last run |
6515 | min s ( pulses) | same as last run except: positron dipoles set to 8 MeV, increased current and rep rate (150 Hz) |
6516 | min s ( pulses) | same as last run except: positron dipoles set to 6 MeV, |
6517 | 2 min 18 s ( pulses) | same as last run except: Magnet is out |
6518 | 7 min 10s ( pulses) | same as last run except: positron dipoles set to 8 MeV, sweep Magnet is out |
6519 | min s ( pulses) | same as last run except: sweep Magnet is In positron bending mode |
6520 | min s ( pulses) | same as last run except: sweep Magnet is In electron bending mode |
FC -vs- 90A beam stop correlation
FC = Aluminum brick 2" from exit window near NaI detectors
50 Ohm scope termination
90 A BS (nVs) | FC (nVs) |
47 | 25 |
24 | 11.9 |
13 | 6 |
6.1 | 2.3 |
4.8 | 1.8 |