Difference between revisions of "TF CPAA Log"

From New IAC Wiki
Jump to navigation Jump to search
Line 12: Line 12:
 
|-
 
|-
 
|}
 
|}
 +
 +
===6/21/13===
 +
 +
{|border="1"  | cellpadding="20" cellspacing="0  class="wikitable"
 +
|-
 +
|run number || Source|| Detector || Disc (V) || Atten (dB) || Comments
 +
|-
 +
|5362 || 9 uCi Na-22  ||  B || 0.64 || 9 ||
 +
|-
 +
|5363 || 10 uCi Co-60 ||  B || 0.64 || 9||
 +
|}
 +
  
 
===6/25/13===
 
===6/25/13===

Revision as of 23:24, 25 June 2013

DAQ setup

ADC readout

Running configuration 1495SA (v1495 TS with Scaler and Adc)

run number conditions
5352 looking for HpGE spectrum using 1 micro-Curie Na-22 source

6/21/13

run number Source Detector Disc (V) Atten (dB) Comments
5362 9 uCi Na-22 B 0.64 9
5363 10 uCi Co-60 B 0.64 9


6/25/13

run number conditions
5396 1 uCi Na-22 source using Detector B, atten = 9db
5397 1 uCi Na-22 source using Detector B, atten = 6db, rate is about 140 Hz, discriminator = 0.63 V
5398 1 uCi Co-60 source using Detector B, atten = 6db, rate is about 200 Hz, discriminator = 0.63 V
5399 10 uCi Co-60 source using Detector B, atten = 6db, rate is about 1460 Hz, discriminator = 0.63 V, R5399 ADC4.png
5400 9 uCi Na-22 source using Detector B, atten = 6db, rate is about 850 Hz, discriminator = 0.63 V,R5400 ADC4.png


PAA_CoincidenceCounting PAA_Research