| + | Consider the neutron knock out reaction on Gold  | ||
| + | |||
| + | <math>{197 \atop\; }Au (\gamma,n){196 \atop \; }Au</math> | ||
| + | |||
| + | Au-196 decays with a half life 6.183 days of by electron capture to Platinum (Pt-196) 92% of the time. | ||
| + | |||
| + | There are two dominant photon energies of 333.03 keV and 355.73 keV.  67% of the time Au-196 goes to the 2+ excited state of Pt-196 after  34.15 ps .  24.7%  of the time it decays to the next higher energy 2+  state of Pt-196  after 33.8 ps and then proceeds to emitt a 333.03 keV photon as it transitions to the lower 2+ state where it will emitt a 355.73 keV photon on its way to the ground state. | ||
| + | |||
| + | |||
| [[File:GoldLinesS333_04222013.png| 200 px]] | [[File:GoldLinesS333_04222013.png| 200 px]] | ||
Revision as of 18:08, 9 May 2013
Irradiation of Silver coins from Deep Blue Marin performed on April 22, 2013
Large Coin
Raw Spectrum
Calibration
|  |  |   | 
| Linear fit using several sources | Zoom in to the most intense line | The most intense line seems to be from positron annihilation | 
Energy Calibrated spectrum
Peak Ratios
Ratio of 511 and
- Silver lines
| Coin Size | 511/451 ratio | 511/748 ratio | 511/1046 ratio | 
| Large | 87740/6639 =13.2 | 87740/2962=29.6 | 87740/2803 = 31.3 | 
| Medium | 31950/2938 =10.9 | 31950/1239 =25.8 | 31950/1283=24.9 | 
| Small | 87090/8184=10.6 | 87090/3790 =22.98 | 87090/3578=24.34 | 
- Gold lines
Consider the neutron knock out reaction on Gold
Au-196 decays with a half life 6.183 days of by electron capture to Platinum (Pt-196) 92% of the time.
There are two dominant photon energies of 333.03 keV and 355.73 keV. 67% of the time Au-196 goes to the 2+ excited state of Pt-196 after 34.15 ps . 24.7% of the time it decays to the next higher energy 2+ state of Pt-196 after 33.8 ps and then proceeds to emitt a 333.03 keV photon as it transitions to the lower 2+ state where it will emitt a 355.73 keV photon on its way to the ground state.
| Coin Size | 333 keV | 356 keV | 333/356 ratio | 
| Large |  |  | 5397/3672=1.47 | 
| Medium |  |  | 2062/1432=1.44 | 
| Small |  |  | 5552/3956 =1.40 | 