Difference between revisions of "2-Neutron Correlation"

From New IAC Wiki
Jump to navigation Jump to search
Line 31: Line 31:
 
* The number of neutrons hitting the detector per pulse is found as <math>2.3*\frac{\Delta \Omega}{4\pi}</math>
 
* The number of neutrons hitting the detector per pulse is found as <math>2.3*\frac{\Delta \Omega}{4\pi}</math>
 
** @ 1 meter => 0.0198 neutrons hitting the detector per pulse
 
** @ 1 meter => 0.0198 neutrons hitting the detector per pulse
** @ 70 cm => 0.379 neutrons hitting the detector per pulse  
+
** @ 70 cm => 0.0379 neutrons hitting the detector per pulse  
 
* Taking into account the efficiency of the detector <math>\epsilon_0</math>, the number detected per pulse can be found as <math>2.3*\frac{\Delta \Omega}{4\pi}*\epsilon_0</math>  
 
* Taking into account the efficiency of the detector <math>\epsilon_0</math>, the number detected per pulse can be found as <math>2.3*\frac{\Delta \Omega}{4\pi}*\epsilon_0</math>  
 
** @ 1 meter from source => (<math>0.0198*\epsilon_0</math>) neutrons detected per pulse
 
** @ 1 meter from source => (<math>0.0198*\epsilon_0</math>) neutrons detected per pulse

Revision as of 20:50, 30 May 2012

Big Detector Solid Angle Calculations

MCNPX Simulation
  • 14 MeV neutron source, emitted isotropically ([math]4\pi[/math])
  • Detector placed 1m away from source

Mcnpxsetup.png

  • face of the detector is 15.24cm x 76.2cm, and 3.6cm deep

DetectorDimensions.png

The solid angle can be found from the number of particles hitting the detector as:
[math]\Delta \Omega = 4\pi*\frac{hits}{hits + misses}[/math]

Results
  • Out of 1E9 neutrons generated, 8618287 neutrons hit the detector
    • [math]\Delta \Omega = 0.108 Sr[/math]
      • if the detector is placed 70cm away from the source, [math]\Delta \Omega = 0.207 Sr[/math]
  • As a test to verify our results
    • We change the detector size to 2cm by 2cm and used 1E9 neutrons again
    • 32061 neutrons struck the detector
    • [math]\Delta \Omega = 0.0004 Sr[/math]
  • And, as a second test to verify our results
    • We change the detector size to 1cm by 1cm and used 1E9 neutrons again
    • 7965 neutrons struck the detector
    • [math]\Delta \Omega = 0.0001 Sr[/math]
Now, what neutron singles rate into the detector should correspond to 1 fission per pulse?
  • If we have 1 fission per pulse and each fission emits on average 2.3 neutrons, we should expect 2.3 neutrons/pulse
  • The number of neutrons hitting the detector per pulse is found as [math]2.3*\frac{\Delta \Omega}{4\pi}[/math]
    • @ 1 meter => 0.0198 neutrons hitting the detector per pulse
    • @ 70 cm => 0.0379 neutrons hitting the detector per pulse
  • Taking into account the efficiency of the detector [math]\epsilon_0[/math], the number detected per pulse can be found as [math]2.3*\frac{\Delta \Omega}{4\pi}*\epsilon_0[/math]
    • @ 1 meter from source => ([math]0.0198*\epsilon_0[/math]) neutrons detected per pulse
    • @ 70 cm from source => ([math]0.0379*\epsilon_0[/math]) neutrons detected per pulse

Go Back