Difference between revisions of "EG1BFragmentationTestTalk"
Line 121: | Line 121: | ||
|}<br> | |}<br> | ||
One can conclude from the above Figure that the inclusive corrections do not impact a single pion production for the exclusive cases.<br> | One can conclude from the above Figure that the inclusive corrections do not impact a single pion production for the exclusive cases.<br> | ||
+ | =Asymmetries= | ||
[https://wiki.iac.isu.edu/index.php/Delta_D_over_D Go Back] | [https://wiki.iac.isu.edu/index.php/Delta_D_over_D Go Back] |
Revision as of 19:33, 29 May 2012
Fragmentation Test
The goal of this work is to measure the fragmentation function dependence on the Bjorken scaling variable (
Data Files
The data files from the EG1b experiment chosen for this analysis are listed below
Run Set | Target Type | Torus Current(A) | Target Polarization | Half Wave Plane(HWP) |
28100 - 28102 | ND3 | +2250 | -0.18 | +1 |
28106 - 28115 | ND3 | +2250 | -0.18 | -1 |
28145 - 28158 | ND3 | +2250 | -0.20 | +1 |
28166 - 28190 | ND3 | +2250 | +0.30 | +1 |
28205 - 28217 | NH3 | +2250 | +0.75 | +1 |
28222 - 28236 | NH3 | +2250 | -0.68 | +1 |
28242 - 28256 | NH3 | +2250 | -0.70 | -1 |
28260 - 28275 | NH3 | +2250 | +0.69 | -1 |
28287 - 28302 | ND3 | -2250 | +0.28 | +1 |
28306 - 28322 | ND3 | -2250 | -0.12 | +1 |
28375 - 28399 | ND3 | -2250 | +0.25 | -1 |
28407 - 28417 | NH3 | -2250 | +0.73 | -1 |
28456 - 28479 | NH3 | -2250 | -0.69 | +1 |
EG1b Runs used for Analysis (Run Sets, Target Type, Torus Current, Target Polarization, HWP). |
Electron-Pion separation
The CLAS trigger system is a coincidence of the negatively charged particle track detected in the electromagnetic calorimeter and cherenkov counter in
EC Cuts
The energy deposited in the calorimeter for electrons and pions is different. Pions are minimum ionizing charged particles when their momentum is above ~ 0.8 GeV and therefore the energy they deposit in the calorimeter is momentum independent. On the other hand, electrons produce photoelectrons and generate an electromagnetic shower releasing energy into the calorimeter that is proportional to their momentum. The following cut is introduced to take advantage of this feature:
vs before and after EC cuts ( , for EC inner - ). After applying EC cuts about 46 % of the events have been removed from the electron sample. |
Cherenkov Cuts
In addition to the cut on the energy deposited into the electromagnetic calorimeter, misidentified electrons are reduced by requiring a signal in the threshold CLAS Cherenkov detector. Pion's misidentified as electrons have been shown to produce around ~1.5 photoelectons (PEs) in the Cherenkov detector, as shown below. Geometrical cuts on the location of the particle at the entrance to the Cerenkov detector were applied to reduce the pion contamination. The second histogram below shows that, after these cuts, the peak around 1.5 PEs is substantially reduced. It appears, that pion contamination in electron sample is
The number of photoelectrons before and after OSI Cuts. |
SIDIS Analysis
Inclusive Electron Detection Efficiency
A comparison of the Inclusive electron rates observed in the scintillator paddles that will be used to reconstruct electrons for SIDIS events. |
Ratios of the inclusive electron rate, normalized using the gated faraday cup, of scintillator paddles 5 and 10 were measured. The two ratios are constructed to quantify the CLAS detectors ability to observe the same electron kinematics in scintillator paddle #5 for a positive Torus polarity and scintillator #10 using the negatie Torus polarity.
Notice the above ratios are statistically the same. The semi-inclusive analysis to be performed in this thesis will be taking ratios using an ND3 and and NH3 target. Below is the observed ratio comparing the inclusive electrons observed in scintillator #5 for a positive torus polarity and ND3 target to the electrons observed in scintillator #10 when the torus polarity is negative and the target is NH3.
The above ratios, which have been observed to be ammonia target independent, indicate a difference in an electron detector efficiency when the Torus polarity is flipped. An electron detection efficiency "correction coefficient" is defined in terms of the above ratio and measured to be
Exclusive Event Reconstruction Efficiencies
The MAID 2007 model has predictions of the total cross section for the following two cases, that are related to our work:
+ proton + neutron |
+ neutron + proton |
The difference between the measured | to exclusive ratio to the ratio predicted by MAID 2007.
One can conclude from the above Figure that the inclusive corrections do not impact a single pion production for the exclusive cases.