2-Neutron Correlation: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 5: Line 5:
* Detector placed 1m away from source<br />
* Detector placed 1m away from source<br />
[[File:mcnpxsetup.png | 500px]]
[[File:mcnpxsetup.png | 500px]]
** face of the detector is 15.24cm x 76.2cm, and 3.6cm deep<br />
 
* face of the detector is 15.24cm x 76.2cm, and 3.6cm deep<br />
[[File:DetectorDimensions.png | 500px]]
[[File:DetectorDimensions.png | 500px]]



Revision as of 19:15, 18 May 2012

Big Detector Solid Angle Calculations

MCNPX Simulation
  • 14 MeV neutron source, emitted isotropically ([math]\displaystyle{ 4\pi }[/math])
  • Detector placed 1m away from source

  • face of the detector is 15.24cm x 76.2cm, and 3.6cm deep

The solid angle can be found from the number of particles hitting the detector as:
[math]\displaystyle{ \Delta \Omega = 4\pi*\frac{hits}{hits + misses} }[/math]

Results
1E9 Neutrons generated
  • 8618287 neutrons hit the detector
  • [math]\displaystyle{ \Delta \Omega = 0.108 Sr }[/math]
As a test to verify our results
We change the detector size to 1cm by 1cm and used 1E9 neutrons again
  • 32061 neutrons struck the detector
  • [math]\displaystyle{ \Delta \Omega = 0.0004 Sr }[/math]

Go Back