Difference between revisions of "Beam Text May 17 2012"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
| Line 28: | Line 28: | ||
| 3) Camera in? | 3) Camera in? | ||
| + | |||
| + | = Energy Scan at 10 MeV = | ||
| + | |||
| + | |||
| + | {| border="1" | ||
| + | | Energy Switch || Out (High En Range) | ||
| + | |- | ||
| + | | Dipole Coil Current || 33 | ||
| + | |- | ||
| + | |  e- Beam Energy  () || 15.6004336 MeV (mapping ) | ||
| + | |- | ||
| + | | Solenoid 1     ||    A   | ||
| + | |- | ||
| + | | Solenoid 2      ||     A | ||
| + | |- | ||
| + | | Gun Hor        || 0  A | ||
| + | |- | ||
| + | | Gun Ver         ||0 A | ||
| + | |- | ||
| + | |Output Hor      || 0.4 A | ||
| + | |- | ||
| + | | Output Ver     ||0.3 A | ||
| + | |- | ||
| + | | Rep Rate     || 6 | ||
| + | |- | ||
| + | |   Gun HV   ||  8.99(Knob Setting) | ||
| + | |- | ||
| + | |   Gun Grid Voltage   || 10 (Knob Setting) | ||
| + | |- | ||
| + | |   RF frequency   ||2856.291 MHz | ||
| + | |- | ||
| + | |   Modulator HV Power Supply   || 4.84 (Knob Setting) | ||
| + | |- | ||
| + | |  RF macro Pulse Length (FWHM)  || 300 ns | ||
| + | |-   | ||
| + | |Q1  (A)|| 0 | ||
| + | |-   | ||
| + | |Q2  (A)|| 0 | ||
| + | |-   | ||
| + | |Q3  (A)|| 0 | ||
| + | |-   | ||
| + | |Q4  (A)|| 0 | ||
| + | |-   | ||
| + | |Q5  (A)|| 0 | ||
| + | |-   | ||
| + | |Q6  (A)|| 0 | ||
| + | |- | ||
| + | |  Peak Current on FC 1 (45 deg)   || 88.8 mAmps | ||
| + | |- | ||
| + | |  Peak Current on FC 2 (45 deg)   || 26.4 mAmps | ||
| + | |- | ||
| + | |  Scope on FC 1  ||  [[File:hrrl_26Apr2012_EnTest_4MeV_FC1_cur.png | 200 px]] | ||
| + | |- | ||
| + | |  Scope on FC 2  ||  [[File:hrrl_26Apr2012_EnTest_4MeV_FC2_cur.png | 200 px]] | ||
| + | |- | ||
| + | |- | ||
| + | | Beam Spot ||  [[File:hrrl_26Apr2012_EnTest_15MeV_beam_im.png | 200 px]]  | ||
| + | |} | ||
Revision as of 04:01, 17 May 2012
Preparation
0. MATLAB emittance analysis: (working?) -- yes
1. Magnets: --Working
2. Camera: (a)--Working, (b)--shielding-good,(c) Sync? -- good
3. Flags: --Working
4. Farady Cup: hocked up? --yes
5. Blank off for camera on? --good
6. Gas bottle for valve full? --Yes
7. Gas bottle for flags full? --Yes
8. 3 Pickup Coils (Green Torroids): (1)@gun: hocked-up; (2)@accelerator exit: hocked-up to 2 red strip wire. Now connected to linac monitor panel which labeled as "J12 from back", "Scan field Mon" from front. (3)@end of beamline:
Check List Before Start
1) Valve exit of cavity opened?
2) Faraday cups are hocked up?
3) Camera in?
Energy Scan at 10 MeV
| Energy Switch | Out (High En Range) | 
| Dipole Coil Current | 33 | 
| e- Beam Energy () | 15.6004336 MeV (mapping ) | 
| Solenoid 1 | A | 
| Solenoid 2 | A | 
| Gun Hor | 0 A | 
| Gun Ver | 0 A | 
| Output Hor | 0.4 A | 
| Output Ver | 0.3 A | 
| Rep Rate | 6 | 
| Gun HV | 8.99(Knob Setting) | 
| Gun Grid Voltage | 10 (Knob Setting) | 
| RF frequency | 2856.291 MHz | 
| Modulator HV Power Supply | 4.84 (Knob Setting) | 
| RF macro Pulse Length (FWHM) | 300 ns | 
| Q1 (A) | 0 | 
| Q2 (A) | 0 | 
| Q3 (A) | 0 | 
| Q4 (A) | 0 | 
| Q5 (A) | 0 | 
| Q6 (A) | 0 | 
| Peak Current on FC 1 (45 deg) | 88.8 mAmps | 
| Peak Current on FC 2 (45 deg) | 26.4 mAmps | 
| Scope on FC 1 | 200 px | 
| Scope on FC 2 | 200 px | 
| Beam Spot | 200 px |