Revision as of 00:48, 16 March 2012
Accelerator Configuration
- Accelerator Settings
| beam energy | 6.8 MeV | 
| Beam type: | Electron | 
| I_average: | 0.3 nA | 
| I_peak: | 0.05 A 0.006 duty factor | 
| pulse width: | 10 s (it seems on 200 s is possible?) | 
| Rate: | 60 Hz | 
| PEPPO Spectrometer: | 151.3 A | 
Set HV to Detectors
| Signal channel | HV dac | HV (V) | |
| Detectors #1 | A1 | 2.4 | 960 | 
| Detectors #2 | A2 | 3.0 | 1200 | 
Scope Pictures
CH1: Beam Sync CH2: A1 CH3: A2
| Target | Pictures | 
| No Target |     | 
| Chromox Target |     | 
Annihilation Counter Runs
- Signal Definitions for Trigger logic
- SYNC:=60 Hz sync pulse 200 micro seconds long
- Det1:= Annihilation Counter #1 (HV1)
- Det2:=Annihilation Counter #2 (HV2)
data analysis
Negative Energy ?
This run 2902, Int_Ch14 histogram. Why there is negative?
Pulses
run 2905
1st 100 puleses
pulse that only partially read-in: