− | Emittance Measurement of Varian Medical Linac | + | ='''Emittance Measurement of Varian Medical Linac'''= |
= Abstract = | = Abstract = | ||
Emittance of Varian High Rep-Rate Linac (HRRL) was measured with Optical Transition Radiation (OTR) at 14 MeV. Electron beam was observed at 10 <math>\mu m </math> thick Al screen. Projection of beam appear to be sharper than Gaussian distribution, and super-Gaussian distribution were fitted. Quadrupole scanning method shows that horizontal and vertical are <math>11.4 \pm 0.6~\mu m</math> and <math> 9.3 \pm 1.8~\mu m</math> respectively. | Emittance of Varian High Rep-Rate Linac (HRRL) was measured with Optical Transition Radiation (OTR) at 14 MeV. Electron beam was observed at 10 <math>\mu m </math> thick Al screen. Projection of beam appear to be sharper than Gaussian distribution, and super-Gaussian distribution were fitted. Quadrupole scanning method shows that horizontal and vertical are <math>11.4 \pm 0.6~\mu m</math> and <math> 9.3 \pm 1.8~\mu m</math> respectively. |
Revision as of 02:29, 2 November 2011
Emittance Measurement of Varian Medical Linac
Abstract
Emittance of Varian High Rep-Rate Linac (HRRL) was measured with Optical Transition Radiation (OTR) at 14 MeV. Electron beam was observed at 10
thick Al screen. Projection of beam appear to be sharper than Gaussian distribution, and super-Gaussian distribution were fitted. Quadrupole scanning method shows that horizontal and vertical are and respectively.