| Line 29: | Line 29: | ||
|-  | |-  | ||
|2349||Centered||In ||Open ||Out||No ||align="left"|PS Rate is: R(upstream) =  404/35489 = 0.011 e+/pulse.    | |2349||Centered||In ||Open ||Out||No ||align="left"|PS Rate is: R(upstream) =  404/35489 = 0.011 e+/pulse.    | ||
| + | |-  | ||
| + | |2350||Centered||In ||Open ||Out||No ||align="left"|PS Rate is: R(upstream) =  404/35489 = 0.011 e+/pulse. Improved shielding around dump  | ||
|-  | |-  | ||
|}  | |}  | ||
Revision as of 18:03, 9 September 2011
summary what was done
| Run # | Beam | Dump magnet | Collimator | Radiator | Target | Comments | 
|---|---|---|---|---|---|---|
| 2339 | Up 2 mm | In | Open | Up 2 mm | No | PS Rate is: R(upstream) = 2648/35092 = 0.075 e+/pulse, R(downstream) = 3191/35092 = 0.091 e+/pulse | 
| 2341 | Up 2 mm | In | Open | Out | No | PS Rate is: R(upstream) = 1088/35494 = 0.031 e+/pulse, R(downstream) = 1328/35494 = 0.037 e+/pulse. About 59% of photons are coming from the radiator. Bad | 
| 2342 | Down 2 mm | In | Open | Out | No | PS Rate is: R(upstream) = 1586/36678 = 0.043 e+/pulse, R(downstream) = 1888/36678 = 0.051 e+/pulse | 
| 2343 | Down 2 mm | In | Open | Down 2 mm | No | PS Rate is: R(upstream) = 2232/35488 = 0.063 e+/pulse. About 32% of photons are coming from the radiator. Bad | 
| 2344 | Centered | In | Open | Centered | No | PS Rate is: R(upstream) = 2683/35095 = 0.076 e+/pulse | 
| 2345 | Centered | In | Open | Out | No | PS Rate is: R(upstream) = 1039/35094 = 0.029 e+/pulse. About 62% of photons are coming from the radiator. Bad | 
| 2346 | Centered | In | Open | Out | No | PS Rate is: R(upstream) = 1286/35885 = 0.036 e+/pulse. Improved shielding around dump. | 
| Based on the previous results the beam is total crap, so beam turn up. | ||||||
| 2349 | Centered | In | Open | Out | No | PS Rate is: R(upstream) = 404/35489 = 0.011 e+/pulse. | 
| 2350 | Centered | In | Open | Out | No | PS Rate is: R(upstream) = 404/35489 = 0.011 e+/pulse. Improved shielding around dump | 
Beam Realignment
(Screen shot using Phosphorous screen)
(Electron beam on glass)
(12pm upstream view screen)
(12pm downstream view screen)