Difference between revisions of "05/13/2011 coincidence test"
Jump to navigation
Jump to search
Line 61: | Line 61: | ||
|- | |- | ||
!PS1 | !PS1 | ||
− | |<math>\ | + | |<math>3229\pm56.8</math>||20 min||<math>2.69\pm0.05</math> |
|- | |- | ||
!PS2 | !PS2 | ||
− | |<math>\ | + | |<math>3192\pm56.5</math>||20 min||<math>2.66\pm0.05</math> |
|- | |- | ||
!PS1+PS2 | !PS1+PS2 | ||
− | |<math>\ | + | |<math>59\pm7.7</math>||20 min||<math>(4.9\pm0.6)\cdot 10^{-2}</math> |
|} | |} | ||
Revision as of 22:14, 13 May 2011
Set up like that:
the distance between PS and n's PMT is abot 80 cm
The voltages and thresholds are as below. Note: I increased my thresholds for PS1 and PS2 from 80 mV up to 100 mV according to mu previous calibration threshold line.
PMT voltage, V | threshold, mV | discr. width, ns | |
---|---|---|---|
PS1 | -1500 | -80 | 100 |
PS1 | -1500 | -80 | 100 |
n's | -1500 | -200 | 10 |
Let's do first the coincidence test PS1+PS2
counts | time | counts/sec | |
---|---|---|---|
PS1 | 20 min | ||
PS2 | 20 min | ||
PS1+PS2 | 20 min |
The scope picture of PS1+PS2 coincidence event like:
Let's do second the coincidence test PS1+PS2+n's
counts | time | counts/sec | |
---|---|---|---|
PS1 | 20 min | ||
PS2 | 20 min | ||
PS1+PS2 | 20 min |
The scope picture of PS1+PS2 coincidence event like: