I did some counts test like:

Detector1.png


The powers were:

PS1 and PS2:  -1000 V
n's: -1100 V

The PMT for n's detectors is PMT HAMAMATSU R580 with supply voltage 1250/1500 V. But I have used the value above, because I though the counts rate was reasonable. See my table below.

The thresholds were:

PS1 and PS2:  -80 mV
n's: -60 mV


Let see what we have. First without CF-243 source:

counts/min counts/min counts/min
PS1 153 counts/min 170 counts/min
PS2 150 counts/min 173 counts/min
n's 358 counts/min
PS1+PS2 3.8 5.8 6.0