HRRL 03-17-2011: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Setisadi (talk | contribs)
Setisadi (talk | contribs)
Line 85: Line 85:
=== 20 mA, Positive Current, X projection ===
=== 20 mA, Positive Current, X projection ===


[[File:HRRL 03-17-2011_Results_Q1_20mA_Pos_SupGau_X.png | 300 px]]
emit=0.447 +- 0.001 mm*mrad, emit_norm=12.255 +- 0.040 mm*mrad
beta=1.31512 +- 0.00000, alpha=1.0949 +-0.0007






[[HRRL_Emittance_Measurements_March14-18-2011]]
[[HRRL_Emittance_Measurements_March14-18-2011]]

Revision as of 04:34, 14 April 2011

Accelerator Tuning

Good Tune Used for good Scan

By Dr. Kim

Solenoid 1 6.8 A
Solenoid 2 10.4 A
Gun Ver -0.2 A
Gun Hor +0.4 A
Output Hor -1.4A
Output Ver -0.5 A
Gun HV +9.75 (Knob Setting)
Gun Grid Voltage 5.25 (Knob Setting)
RF frequency 2855.816 MHz
Modulator HV Power Supply 4.42 (Knob Setting)
RF macro Pulse Length (FWHM) 200 ns
Peak Current on FC 37.2 mAmps
Scope on FC
e- Beam Energy 14 MeV



Calibration

image OTR image cal_h (mm/px) cal_v (mm/px)
0.04308 0.04204
0.04320 0.04228
0.04349 0.04181
0.04323 0.04196
0.04337 0.04212
mean (mm/px) mean (mm/px)
[math]\displaystyle{ 0.04327 \pm 0.00016 }[/math] [math]\displaystyle{ 0.04204 \pm 0.00018 }[/math]


Results

Q1

42 mA, Positive Current, X projection

emit=0.389 +- 0.001 mm*mrad, emit_norm=10.658 +- 0.034 mm*mrad

beta=1.28826 +- 0.00004, alpha=0.9378 +-0.0007


42 mA, Negative Current, Y projection

emit=0.269 +- 0.001 mm*mrad, emit_norm=7.370 +- 0.024 mm*mrad

beta=0.9271 +- 0.0001, alpha=0.1922 +-0.0005


20 mA, Positive Current, X projection

emit=0.447 +- 0.001 mm*mrad, emit_norm=12.255 +- 0.040 mm*mrad

beta=1.31512 +- 0.00000, alpha=1.0949 +-0.0007


HRRL_Emittance_Measurements_March14-18-2011