Difference between revisions of "HRRL 03-18-2011"
Jump to navigation
Jump to search
| Line 74: | Line 74: | ||
|(A) || || | |(A) || || | ||
|- | |- | ||
| − | | (-0.3)||[[File: | + | | (-0.3)||[[File:OTR_Q1Scan03182011_10.png | 100 px]] ||[[File:FC_Q1Scan03182011_10.png | 100 px]] |
| − | |||
|} | |} | ||
Revision as of 17:55, 18 March 2011
Tune parameters
Previous Tune at the higher energy
| Solenoid 1 | 5.4 A |
| Solenoid 2 | 5.5 A |
| Gun Ver | -0.2 A |
| Gun Hor | +0.4 A |
| Output Hor | -0.5 A |
| Output Ver | -0.5 A |
| Gun HV | +9.75 (Knob Setting) |
| Gun Grid Voltage | 5.25 (Knob Setting) |
| RF frequency | 2855.813 MHz |
| Modulator HV Power Supply | 4.11 (Knob Setting) |
| RF macro Pulse Length (FWHM) | 200 ns |
Solenoid comparison with yesterdays higher energy tune
Quad Scans
To test reproducibility from yesterday. Scan at 40, 20, 10, 5 mA peak currents. Scan twice on each Current.
Do Energy Scan
Bend the beam through 45 bending dipole, take images on the scope of FC and YAG images.
| D1 current | Energy | FC peak Volt | Pic |
| (A) | MeV | mV | |
| 28 | 11.85 | 39 | |
| 29 | 12.3 | 74 | |
| 30 | 12.74 | 93 | |
| 30.5 | 12.96 | 65 | |
| 30.7 | large uncertainty | 22 |
Quad 1 Scan
| Quad 1 | OTR Pict | FC pict |
| (A) | ||
| (-0.3) |