HRRL 03-15-2011: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Foretony (talk | contribs)
Setisadi (talk | contribs)
No edit summary
Line 19: Line 19:
|}
|}


=Quad Centering=
=Scan Results=
==Scan_Quad1 ==
===163mA===
[[File:HRRL_05-15-3011-Scan_Q1_163mA_Par_Fit_x.png]]
x-projection:
 
emit=0.560 +- 0.003 mm*mrad, emit_norm=10.958 +- 0.056 mm*mrad
 
beta=1.551 +- 0.00929457519888524270000000000000, alpha=-1.266 +-0.008
 
[[File:HRRL_05-15-3011-Scan_Q1_163mA_Par_Fit_y.png]]
 





Revision as of 02:36, 16 March 2011

Quad scan

1.) deliver 165 mA peak current to FC with all Quads off Ouput corrector off (H2=0,V2=0) 2.) Use Q1-Q3 to make smallest spot on the OTR

3.) Use Output corrector to center beam spot onto OTR. Record transmission.

Quad scan using Q4

Do quick quad scan with analog camera


Install digital and shielding

Quad current STOR image
File:Image.png

Scan Results

Scan_Quad1

163mA

x-projection:
emit=0.560 +- 0.003 mm*mrad, emit_norm=10.958 +- 0.056 mm*mrad 
beta=1.551 +- 0.00929457519888524270000000000000, alpha=-1.266 +-0.008 



HRRL_Emittance_Measurements_March14-18-2011