FC calibration (by view screen monitoring) 3/1/11: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Shaproma (talk | contribs)
No edit summary
Shaproma (talk | contribs)
No edit summary
Line 9: Line 9:
#red line is the fitting line for beam up
#red line is the fitting line for beam up
#green line is the fitting line for beam down
#green line is the fitting line for beam down
#green line is the fitting line for beam up and down
#black line is the fitting line for beam up and down


We can see that all three line is almost the same so we can use the fitting line for whole range of kicker magnet which is
We can see that all three line is almost the same so we can use the fitting line for whole range of kicker magnet which is

Revision as of 21:50, 1 March 2011

Go Back



Here are:

  1. red line is the fitting line for beam up
  2. green line is the fitting line for beam down
  3. black line is the fitting line for beam up and down

We can see that all three line is almost the same so we can use the fitting line for whole range of kicker magnet which is

[math]\displaystyle{ x(cm)= 0.059 + 0.028\cdot I(Ampers) }[/math]


Go Back