Difference between revisions of "FC calibration (by view screen monitoring) 3/1/11"
Jump to navigation
Jump to search
(Created page with '[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] 1000 px [https://wiki.iac.isu.edu/index.php/PhotoFiss…') |
|||
Line 2: | Line 2: | ||
− | [[File:FC Calibration.png | 1000 px]] | + | [[File:File:FC Calibration 3.1.11.png | 1000 px]] |
+ | |||
+ | Here are: | ||
+ | |||
+ | #red line is the fitting line for beam up | ||
+ | #green line is the fitting line for beam down | ||
+ | #green line is the fitting line for beam up and down | ||
+ | |||
+ | We can see that all three line is almost the same so we can use the fitting line for whole range of bending magnet which is | ||
+ | |||
+ | <math>x(cm)= 0.059 + 0.028\cdot I(Ampers)</math> | ||
[https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] | [https://wiki.iac.isu.edu/index.php/PhotoFission_with_Polarized_Photons_from_HRRL Go Back] |