Difference between revisions of "Emittance/TWISS parameter extraction"

From New IAC Wiki
Jump to navigation Jump to search
Line 13: Line 13:
 
[[File:ISU_3.jpeg|200px|thumb|left|X beam size squared vs K1*L]]
 
[[File:ISU_3.jpeg|200px|thumb|left|X beam size squared vs K1*L]]
 
[[File:ISU_4.jpeg|200px|thumb|center|CEBAF graphical emittance tool with X data and results shown]]
 
[[File:ISU_4.jpeg|200px|thumb|center|CEBAF graphical emittance tool with X data and results shown]]
 +
 +
|-
 +
|            | emittance| beta |alpha |
 +
|            | (m-rad)  | (m)  |      |
 +
|-
 +
|X quad scan 1| 1.3e-6  | 0.35 | 2.0  |
 +
|Y quad scan 0| 3.7e-6  | 0.41 | 2.3  |
 +
|-

Revision as of 20:08, 22 October 2010

Using the perl/PDL script, beam sizes for Y (quad scan 0) and X (quad scan 1) were measured. These beam sizes were put into a "sdds" file so the nominal CEBAF emittance/TWISS tool could be used to plot and fit the data.

Two fits are performed a simple Least Squares Fit and one based on MINUIT. The LSF is also used to seed the MINUIT fit.

Y plot and the GUI with results for the first quad scan.

Y beam size squared vs K1*L
CEBAF graphical emittance tool with Y data and results shown



X plot and the GUI with results for the second quad scan.

X beam size squared vs K1*L
CEBAF graphical emittance tool with X data and results shown

|- | | emittance| beta |alpha | | | (m-rad) | (m) | | |- |X quad scan 1| 1.3e-6 | 0.35 | 2.0 | |Y quad scan 0| 3.7e-6 | 0.41 | 2.3 | |-