beam energy | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
25 MeV | 4.13 cm | 6.78 cm | 2.92 cm | 4.79 cm | 9.18 cm > 8.73 cm | 75 cm | 7.49 cm > 5.08 cm | ||||
25 MeV | 4.13 cm | 6.78 cm | 1.95 cm | 3.20 cm | 8.37 cm < 8.73 cm | 111 cm | 4.99 cm < 5.08 cm | ||||
25 MeV | 4.13 cm | 6.78 cm | 1.46 cm | 2.40 cm | 7.98 cm < 8.73 cm | 136 cm | 3.74 cm < 5.08 cm | ||||
44 MeV | 2.35 cm | 3.85 cm | 1.66 cm | 2.72 cm | 5.21 cm < 8.73 cm | 75 cm | 4.26 cm < 5.08 cm | ||||
44 MeV | 2.35 cm | 3.85 cm | 1.11 cm | 1.82 cm | 4.76 cm < 8.73 cm | 111 cm | 2.84 cm < 5.08 cm | ||||
44 MeV | 2.35 cm | 3.85 cm | 0.83 cm | 1.36 cm | 4.53 cm < 8.73 cm | 136 cm | 2.13 cm < 5.08 cm |