Difference between revisions of "Geometry (25 MeV LINAC exit port)"
Jump to navigation
Jump to search
Line 34: | Line 34: | ||
{| border="1" cellpadding="20" cellspacing="0" | {| border="1" cellpadding="20" cellspacing="0" | ||
|- | |- | ||
− | !width= | + | !width=40|collimator diameter |
|<math>\Theta_{critical}</math> | |<math>\Theta_{critical}</math> | ||
|<math>\Theta_{kicker}</math> | |<math>\Theta_{kicker}</math> |
Revision as of 05:49, 13 June 2010
Minimum accelerator energy to run experiment
The minimum energy of accelerator (MeV) is limited by fitting the collimator (
) into the hole ( )
1) Assuming the collimator diameter is
:
2) Assuming the collimator diameter is
:
3) Assuming the collimator diameter is
:
4) In general:
25 MeV geometry
geometry calculation
collimator diameter | |||||||||
---|---|---|---|---|---|---|---|---|---|
4.13 cm | 6.78 cm | 2.92 cm | 4.79 cm | 75 cm | 143 cm | ||||
4.13 cm | 6.78 cm | 1.46 cm | 2.40 cm | 136 cm | 203 cm |
geometry pictures
how it looks 1 ( , box 3"x4" and then pipe 4")
File:Vacuum pipe collimator .png
how it looks 2 ( , box 3"x4" and then pipe 4")
File:Vacuum pipe collimator .png