Difference between revisions of "Geometry (25 MeV LINAC exit port)"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
| Line 7: | Line 7: | ||
| The minimum energy of accelerator (MeV) is limited by fitting the collimator (<math>r_2</math>) into the hole (<math>R</math>) | The minimum energy of accelerator (MeV) is limited by fitting the collimator (<math>r_2</math>) into the hole (<math>R</math>) | ||
| − | + | Assuming the collimator size is <math>\Theta_C/2</math>. | |
|   <math>x_2 + r_2 = R</math> |   <math>x_2 + r_2 = R</math> | ||
Revision as of 03:04, 13 June 2010
Minimum accelerator energy to run experiment
The minimum energy of accelerator (MeV) is limited by fitting the collimator () into the hole ()
Assuming the collimator size is .
25 MeV geometry
critical angle
kicker angle
geometry ()
collimator center position
(wall 1)
(wall 2)
collimator diameter
(wall 1)
(wall 2)
collimator critical angle
:
minimal distance from the wall ()
  
geometry ()
collimator center position
(wall 1)
(wall 2)
collimator diameter
(wall 1)
(wall 2)
collimator critical angle
:
minimal distance from the wall ()
  
Funny pictures...
how it looks 1 (, box 3"x4" and then pipe 4")
File:Vacuum pipe collimator .png
how it looks 2 (, box 3"x4" and then pipe 4")
File:Vacuum pipe collimator .png