Difference between revisions of "Counts Rate (44 MeV LINAC)"
Line 49: | Line 49: | ||
===photonuclear cross section for <math>^{238}U(\gamma , n)</math> reaction=== | ===photonuclear cross section for <math>^{238}U(\gamma , n)</math> reaction=== | ||
− | + | J. T. Caldwell ''et all.,'' Phys. Rev. '''C21''', 1215 (1980): | |
[[File:phofission_sigma_U238.png]] | [[File:phofission_sigma_U238.png]] |
Revision as of 06:04, 26 May 2010
Counts Rate for U238
LINAC parameters used in calculations
1) pulse width 50 ps
2) pulse current 50 A
3) repetition rate 300 Hz
4) energy 44 MeV
Number of electrons/sec on radiator
Number of photons/sec on target
bremsstrahlung
in (10,20) MeV region we have about
0.1 photons/electrons/MeV/r.l
radiation length
r.l.(Ti) = 3.59 cm
radiator thickness = 12.5
steps together...
Alex factor (GEANT4 calculation)
Collimation factor is
6.85 % of total # of photons
then, incident flux on target is
Number of neutrons/sec (yields)
photonuclear cross section for reaction
J. T. Caldwell et all., Phys. Rev. C21, 1215 (1980):
in (10,20) MeV region the average cross section, say, is:
130 mb
target thickness,
Let's target thickness = 1 mm:
neutrons per fission
2.4 neutrons/fission
steps together...yeild
Worst Case Isotropic Neutrons
checking detector distance
we want:
the time of flight of neutron >> the pulse width
take the worst case 10 MeV neutron:
take the neutron detector 1 meter away:
23 ns >> 50 ps <= time resolution is good
geometrical factor
taking real detector 3" x 2" => S is about 40 cm^2
1 meter away
fractional solid angle =
<= geometrical acceptanceYield
the yield per second:
the yield per pulse:
538 neutrons/sec <= this experiment is do able
1.8 neutrons/pulse <= is not good for stopping pulse
Counts Rate for Deuteron
Photonuclear cross section for reaction=
From the paper "Absolute total cross sections for deuteron photodisintegration between 7 and 19 MeV", A. De Graeva and other. Physical Review C, (45), 860, February 1992:
in (10,20) MeV region the average cross section, say, is:
1000 μb
target thickness,
take
, liquid (20°C):
Let's target thickness = 10 cm:
Calibration factor
The only difference from calculations above is:
1) cross section:
1000 μb (D) / 130 mb (238U) = 1/130
2) target thickness:
3) neutrons per reaction:
1 neutron (D) / 2.4 neutrons(238U) = 1/2.4
4) geometrical factor:
assume for now is 1
total calibration factor is:
Yield
saying all other factors is the same =>
the yield per second :
the yield per pulse: