Difference between revisions of "Counts Rate (44 MeV LINAC)"
Jump to navigation
Jump to search
Line 62: | Line 62: | ||
==neutrons per fission== | ==neutrons per fission== | ||
− | 2.4 neutrons/fission | + | '''2.4 neutrons/fission''' |
==steps together...== | ==steps together...== |
Revision as of 22:37, 17 May 2010
LINAC parameters used in calculations
1) pulse width 50 ns
2) pulse current 50 A
3) repetition rate 300 Hz
4) energy 44 MeV
Number of electrons/sec on radiator
Number of photons/sec from radiator
bremsstrahlung
plot from Dale
in (10,20) MeV region we have about
0.1 photons/electrons/MeV/r.l
radiation length
Titanium r.l. is 3.59 cm
take radiator thickness is
steps together...
Collimation factor
assume we collimate 4-6 % of total # of photons (Alex, GEANT calculation)
then, incident flux on target is
Number of neutrons/sec (yields)
cross section
plot from Berman
in (10,20) MeV region the average cross section for
is:130 mb
target thickness,
Assume the target thickness is 1 cm:
neutrons per fission
2.4 neutrons/fission
steps together...
Worst Case Isotropic Neutrons
Let's say we have:
radius detector = 1 cm
1 meter away
fractional solid angle =
<= geometrical acceptancefinally we have
Therefore, this experiment is do able.