==LINAC parameters used in calculations== | ==LINAC parameters used in calculations== | ||
1) pulse width 50 ns <br> | 1) pulse width 50 ns <br> | ||
− | 2) pulse current | + | 2) pulse current 50 A <br> |
− | 3) repetition rate | + | 3) repetition rate 300 Hz <br> |
4) energy 44 MeV <br> | 4) energy 44 MeV <br> | ||
Line 10: | Line 10: | ||
<math> 50ps \times 50A \times 300Hz \times \frac{1\cdot e^-}{1.6\cdot 10^{-19}C} = 0.75 \cdot 10^{13} \frac{e^-}{sec}</math><br><br> | <math> 50ps \times 50A \times 300Hz \times \frac{1\cdot e^-}{1.6\cdot 10^{-19}C} = 0.75 \cdot 10^{13} \frac{e^-}{sec}</math><br><br> | ||
− | ==number of <math>\gamma 's/sec<math> after radiator== | + | ==number of <math>\gamma 's/sec</math> after radiator== |
<math>10^{-3} \frac{\gamma 's}{(e^-\ MeV\ r.l.)} \times 2 \cdot 10^{-4} r.l. \times 44 MeV \times 0.375 \cdot 10^{12} \frac{e^-}{sec}=0.3 \cdot 10^{7} \frac{\gamma}{sec}</math><br><br> | <math>10^{-3} \frac{\gamma 's}{(e^-\ MeV\ r.l.)} \times 2 \cdot 10^{-4} r.l. \times 44 MeV \times 0.375 \cdot 10^{12} \frac{e^-}{sec}=0.3 \cdot 10^{7} \frac{\gamma}{sec}</math><br><br> | ||