Geometry (44 MeV LINAC exit port): Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Oborn (talk | contribs)
No edit summary
Oborn (talk | contribs)
Line 19: Line 19:
==Collimator location==
==Collimator location==


   <math>\Delta_1 = 286\ cm\ \tan(\Theta_C)<br>
   <math>\Delta_1 = 286\ cm\ \tan(\Theta_C)</math><br>
   <math>\Delta_2 = (286 + 183)\ cm\ \tan(\Theta_C)<br>
   <math>\Delta_2 = (286 + 183)\ cm\ \tan(\Theta_C)</math><br>


   <math>x_1 = 286\ cm \  \tan(\Theta_K)</math><br>
   <math>x_1 = 286\ cm \  \tan(\Theta_K)</math><br>

Revision as of 22:18, 20 June 2010

Go Back

90[math]\displaystyle{ ^o }[/math] exit port geometry



Off-axis collimation geometry


Critical and Kicker angles

[math]\displaystyle{ \Theta_C = \frac{m_ec^2}{E} }[/math]
[math]\displaystyle{ \Theta_K = tan^-1\left(\frac{x_1}{286}\right)
                       = tan^-1\left(\frac{1}{\sqrt{2}}\ \frac{\Delta_1}{286}\right)
                       = tan^-1\left(\frac{1}{\sqrt{2}}\ tan(\Theta_C)\right) }[/math]

Collimator location

  [math]\displaystyle{ \Delta_1 = 286\ cm\ \tan(\Theta_C) }[/math]
[math]\displaystyle{ \Delta_2 = (286 + 183)\ cm\ \tan(\Theta_C) }[/math]
  [math]\displaystyle{ x_1 = 286\ cm \  \tan(\Theta_K) }[/math]
[math]\displaystyle{ x_1 = (286 +183)\ cm \ \tan(\Theta_K) }[/math]

Collimator critical angle

 [math]\displaystyle{ \alpha =  }[/math]

Vacuum pipe location ([math]\displaystyle{ \Theta_c/2 }[/math])

collimator location

1) center position:

  [math]\displaystyle{ 286\ cm \cdot \tan (0.47) = 2.35\ cm }[/math]  (wall 1)
[math]\displaystyle{ (286 + 183)\ cm \cdot \tan (0.47) = 3.85\ cm }[/math] (wall 2)

2) collimator diameter:

  [math]\displaystyle{ \Theta_c/2 = 0.67^o/2 = 0.335^o }[/math]
  [math]\displaystyle{ 286\ cm \cdot \tan (0.335) = 1.67\ cm }[/math]  (wall 1)
[math]\displaystyle{ (286 + 183)\ cm \cdot \tan (0.335) = 2.74\ cm }[/math] (wall 2)

collimator critical angle

  [math]\displaystyle{  AB = AC - BD/2 = (2.35 - 1.67/2)\ cm = 1.52\ cm  }[/math]
[math]\displaystyle{ A_1D_1 = A_1C_1 + B_1D_1/2 = (3.85 + 2.74/2)\ cm = 5.22\ cm }[/math]
[math]\displaystyle{ ED_1 = A_1D_1 - A_1E = (5.22 - 1.52)\ cm = 3.70\ cm }[/math]

from triangle [math]\displaystyle{ BED_1 }[/math]:

  [math]\displaystyle{  \tan (\alpha) = \frac{3.70\ cm}{183\ cm} \Rightarrow \alpha = 1.16^o }[/math]

minimal distance from the wall

from triangle FAB:

  [math]\displaystyle{  FA = \frac{AB}{\tan (1.16^o)} = \frac{1.52\ cm}{\tan (1.16^o)} = 75\ cm  }[/math]


Vacuum pipe location ([math]\displaystyle{ \Theta_c/4 }[/math])

collimator location

1) center position:

  [math]\displaystyle{ 286\ cm \cdot \tan (0.47) = 2.35\ cm }[/math]  (wall 1)
[math]\displaystyle{ (286 + 183)\ cm \cdot \tan (0.47) = 3.85\ cm }[/math] (wall 2)

2) collimator diameter:

  [math]\displaystyle{ \Theta_c/4 = 0.67^o/4 = 0.168^o }[/math]
  [math]\displaystyle{ 286\ cm \cdot \tan (0.168) = 0.84\ cm }[/math]  (wall 1)
[math]\displaystyle{ (286 + 183)\ cm \cdot \tan (0.168) = 1.38\ cm }[/math] (wall 2)

collimator critical angle

  [math]\displaystyle{  AB = AC - BD/2 = (2.35 - 0.84/2)\ cm = 1.93\ cm  }[/math]
[math]\displaystyle{ A_1D_1 = A_1C_1 + B_1D_1/2 = (3.85 + 1.38/2)\ cm = 4.54\ cm }[/math]
[math]\displaystyle{ ED_1 = A_1D_1 - AB = (4.54 - 1.93)\ cm = 2.61\ cm }[/math]

from triangle [math]\displaystyle{ BED_1 }[/math]:

  [math]\displaystyle{  \tan (\alpha) = \frac{2.61\ cm}{183\ cm} \Rightarrow \alpha = 0.82^o }[/math]

minimal distance from the wall

from triangle FAB:

  [math]\displaystyle{  FA = \frac{AB}{\tan (0.82^o)} = \frac{1.93\ cm}{\tan (0.82^o)} = 135\ cm  }[/math]

Funny pictures...

how it looks ([math]\displaystyle{ \Theta_c/2 }[/math], pipe 3")


how it looks 1 ([math]\displaystyle{ \Theta_c/4 }[/math], pipe 3")


how it looks 2 ([math]\displaystyle{ \Theta_c/4 }[/math], pipe 3")


how it looks 4 ([math]\displaystyle{ \Theta_c/2 }[/math], pipe (2 1/2)" and then pipe 4")

need to adjust to converter position



how it looks 5 ([math]\displaystyle{ \Theta_c/2 }[/math], box 3"x4" and then pipe 4")

need to adjust to converter position



Go Back