Difference between revisions of "Geometry (44 MeV LINAC exit port)"
Jump to navigation
Jump to search
Line 32: | Line 32: | ||
[[File:beam_up_down5.png]]<br> | [[File:beam_up_down5.png]]<br> | ||
− | |||
=Vacuum pipe= | =Vacuum pipe= |
Revision as of 06:14, 25 May 2010
Some measurements of 90 experimental degree exit port
Critical angle and displacement calculations
Kicker angle and displacement calculations
1 foot = 30.48 cm
accelerator's side wall
detector's side wall
Off-axis collimation geometry
Vacuum pipe
collimator location
1) center position
(wall 1)
(wall 2)
2) assume diameter is
(wall 1)
(wall 2)
collimator critical angle
AB = AC - BD/2 = (2.35 - 1.67/2) cm = 1.52 cm
A1D1 = A1C1 + B1D1/2 = (3.85 + 2.74/2) cm = 5.22 cm
ED1 = A1D1 - AB = (5.22 - 1.52) cm = 3.70 cm
from triangle
:
minimal distance from the wall
1) from triangle QAB:
3) from triangles OPR and QPR:
OQ = OA - QA = (286 - 75) cm = 211 cm
4) minimal distance:
RA = RQ + QA = (61 + 75) cm = 136 cm (from the wall)
OR = OA + RA = (286 + 136) cm = 150 cm (from the wall)