Difference between revisions of "HRRL 7-31-09"
Jump to navigation
Jump to search
Line 84: | Line 84: | ||
==TDC Calibration== | ==TDC Calibration== | ||
− | + | Second pulse width is 80 ns. | |
{| border="1" cellpadding="20" cellspacing="0" | {| border="1" cellpadding="20" cellspacing="0" | ||
|- | |- | ||
− | | Run Number || Scope Image || TDC Histogram || Calculated Time (ns) || Time measured on the scope ns (between the fall the first pulse and rise of the second pulse) | + | | Run Number || Scope Image || TDC Histogram || Calculated Time (ns) || Time measured on the scope ns (between the fall the first pulse and rise of the second pulse) || Time measured on the scope ns (between the fall the first pulse and fall of the second pulse) |
|- | |- | ||
− | | 1238 || [[File:imageTDCCalibration_1.png|200px]] || [[File:imageTDCCalibration_1.gif|200px]] || 169.5 || 160 | + | | 1238 || [[File:imageTDCCalibration_1.png|200px]] || [[File:imageTDCCalibration_1.gif|200px]] || 169.5 || 160 || 80 |
|- | |- | ||
− | | 1239 || [[File:imageTDCCalibration_2.png|200px]] || [[File:imageTDCCalibration_2.gif|200px]] || 135.7 || 130 | + | | 1239 || [[File:imageTDCCalibration_2.png|200px]] || [[File:imageTDCCalibration_2.gif|200px]] || 135.7 || 130 || 50 |
|- | |- | ||
− | | 1240 || [[File:imageTDCCalibration_3.png|200px]] || [[File:imageTDCCalibration_3.gif|200px]] || 111.5 || 110 | + | | 1240 || [[File:imageTDCCalibration_3.png|200px]] || [[File:imageTDCCalibration_3.gif|200px]] || 111.5 || 110 || 30 |
|} | |} | ||
Revision as of 20:23, 5 August 2009
Default HRRL running Conditions
Pulse Width | Rep Rate | Energy | |
8 mA | 100 ns | 1 Hz | 3 MeV |
cable names
CH ID | Description |
2223A1 | Front Scintillator |
2223A2 | Rear Scintilaltor |
2223A3 | ADC Gate From counting house to Experimental Cell |
2223A4 | TDC start pulse from counting house to experimental cell (PMT front + beam Gate) |
2223A5 | Coincidenc between front + rear Scint + Gun pulser to scaler channel 8 |
2223A6 | Metalica sense wire 4 |
2223A7 | Delayed rear PMT pulse to ADC |
2223A8 | Plastica sense wire 4 |
2223A9 | Plastica to scaler channel 4 |
2223A10 | Front scintillator to ADC |
2223A11 | Metalica scaler channel 1 |
2223A12 | DAQ trigger |
DAQ Ntuple names
Ntuple Variable | Description |
ADC5 | Front Scintilator |
ADC1 | Metalica sense wire 4 |
ADC16 | Rear Scintilator |
ADC13 | Plastica sense wire 4 |
TDC1 | Metalica sense wire 4 |
TDC3 | Plastika sense wire 4 |
ADC + Scaler + TDC + V1495
Run Number | Distance to Metallica's Feedthrough tip (cm) | Metalica scaler counts scaler ch 4 | Plastika Scaler Counts scaler ch 1 | Rear PMT + Front PMT + Gun Pulse Counts Scaler Ch 8 | HV S:F:G | Discriminator (mV) | Metalica counts/PMT+Gun pulse |
1263 | 19 | 0 | 1400:-700:980 | 50 |
TDC Measurements
TDC Calibration
Second pulse width is 80 ns.
Actual Measurements
Run Number | Beam Energy (MeV) | Collimator size ~ (cm) | HV S:F:G | Discriminator Threshold (mV) | TDC Histogram |
1296 | 2 | 0.8 | 1400:-700:980 | 50 | |
1297 | 4 | 0.8 | 1400:-700:980 | 50 | |
1298 | 4 | 0.8 | 1400:-700:980 | 50 | 250px |
1299 | 4 | 0.8 | 1400:-700:980 | 50 | 250px |
1304 && 1305 | 4 | 0.2 | 1400:-700:980 | 50 | |
1306 | 2 | 0.8 | 1400:-700:980 | 50 |
VFAT runs
4 MeV beam energy, big collimator.
GEM HV settings:
=3425/3125.Run Number | Card 1 Threshold | Card 2 Threshold |
1300 | 151 | 116 |
1301 | 153 | 118 |
1302 | 155 | 120 |
1303 | 157 | 122 |
GEM HV settings:
=3425/3125.4 MeV beam energy, small collimator.
Run Number | Card 1 Threshold | Card 2 Threshold |
1305 | 151 | 124 |