Difference between revisions of "Determining the uncertainty of Eγ"
Jump to navigation
Jump to search
| Line 24: | Line 24: | ||
<math>P_n=m_nv</math> = 188MeV/c ± 2.2% | <math>P_n=m_nv</math> = 188MeV/c ± 2.2% | ||
| + | |||
| + | Δ<math>\theta_n</math> can be determined knowing that the detector is 3 meters away and the dimensions of the detector are 5cm wide by 5cm tall. | ||
Revision as of 09:14, 12 June 2008
To determine the uncertainty in Eγ we pick an angle for the neutron within [, + Δ ] and a momentum of the neutron between [, + Δ ].
What are reasonable Δ and Δ ?
is determined by time of flight.
Knowns:
= 939.565 ± 0.00028
d = 3 ± 0.005 m
t = 50 ± 1 ns
Fractional Uncertainties
= 0.2c ± 2.2%
= 188MeV/c ± 2.2%
Δ can be determined knowing that the detector is 3 meters away and the dimensions of the detector are 5cm wide by 5cm tall.