Shapes Considered for calculating the Percentage error in results
Shapes Considered for calculating the Percentage error in results
Line 5: Line 5:
* Circle with a radius of 50mm and thickness of 0.0254mm
* Circle with a radius of 50mm and thickness of 0.0254mm
*      Actual Size of the sheet with 0.254mm Thick
*      Actual Size of the sheet with 0.254mm Thick
== Square Section ==
=== Ansys Analysis===
[[Image:Mylar_Square.jpg]]
Total Deformation observed in ANSYS is 1016.6 mm and by hand calculation it is observed to be 1108.6mm
===Hand Calculations==
[[Image:Mylar_rect_table.jpg]]
== Circular Section ==
=== Ansys Analysis===
[[Image:mylar_circular.jpg]]
The Maximum total deformation is observed to be 789.93mm
===Hand Calculations==
[[Image:Mylar_actual.jpg]]

Revision as of 11:50, 9 June 2008

Mylar Linear Small Deflection

Shapes Considered for calculating the Percentage error in results

  • Square with rectangular approach of 100mm x 100mm with a thickness of 0.0254mm
  • Circle with a radius of 50mm and thickness of 0.0254mm
  • Actual Size of the sheet with 0.254mm Thick

Square Section

Ansys Analysis

Total Deformation observed in ANSYS is 1016.6 mm and by hand calculation it is observed to be 1108.6mm

=Hand Calculations

Circular Section

Ansys Analysis

The Maximum total deformation is observed to be 789.93mm