5 Analysis were carried out as follows.
5 Analysis were carried out as follows.
All of them with Carbon rods, No Hexcel sheet, No mylar sheet. Left hinge was constrained, right hinge was allowed to move along the back Plate length(x-axis) and front face of the nose plate was constrained.
All of them with Carbon rods, No Hexcel sheet, No mylar sheet. Left hinge was constrained, right hinge was allowed to move along the back Plate length(x-axis) and front face of the nose plate was constrained.


wire loads 1512N
*wire loads 1512N


Case 1. No gravity
Case 1. No gravity
Line 14: Line 15:




[[Remaining pictures of Case_1]]
The remaining pictures with X, Y, Z Deformations are available at[[Remaining pictures of Case_1]]
The analysis report is available at

Revision as of 21:19, 25 April 2008

5 Analysis were carried out as follows.

All of them with Carbon rods, No Hexcel sheet, No mylar sheet. Left hinge was constrained, right hinge was allowed to move along the back Plate length(x-axis) and front face of the nose plate was constrained.

  • wire loads 1512N

Case 1. No gravity

Figure 4.25.08.1: Total Deformation in analysis Case 1


The remaining pictures with X, Y, Z Deformations are available atRemaining pictures of Case_1 The analysis report is available at