Difference between revisions of "IAC 2-29-08"
Jump to navigation
Jump to search
Line 4: | Line 4: | ||
This time the Sense wire HV is set to 1500 to start | This time the Sense wire HV is set to 1500 to start | ||
+ | |||
+ | 90/10 ArCo2 | ||
+ | |||
+ | {| border="1" |cellpadding="20" cellspacing="0 | ||
+ | |colspan= "3" | HV settings | ||
+ | |- | ||
+ | | Wire || Volts || current (<math>\mu</math>A) | ||
+ | |- | ||
+ | |Sense || 1500 || | ||
+ | |- | ||
+ | |Field || -750 || | ||
+ | |- | ||
+ | |Guard || 750 || | ||
+ | |} | ||
+ | |||
+ | DC preamp at 5.6 Volts | ||
[http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype#IAC_Runs Go Back] | [http://www.iac.isu.edu/mediawiki/index.php/Mini-prototype#IAC_Runs Go Back] |
Revision as of 15:19, 29 February 2008
Leap Day run
DC setup
This time the Sense wire HV is set to 1500 to start
90/10 ArCo2
HV settings | ||
Wire | Volts | current ( | A)
Sense | 1500 | |
Field | -750 | |
Guard | 750 |
DC preamp at 5.6 Volts