Below are the resulting transparency measurements for PbF2 block # 39
12/4/07
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 8:30 |
beam stop: | 10:30 |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns- Dose rate measurements (@1039 hours)
-radiation | 7.5 mR/hr |
-radiation: | 15 mR/hr |
- Transparency Measurements (@1400 hours)
- Transparency Measurements (@1515 hours)
12/5/07
- Accelerator Settings
beam energy | 20 MeV |
Rep Rate: | 30 Hz |
I_peak: | 60 mA/pulse |
pulse width: | 0.1 | s (100 ns)
beam start: | 10:45 |
beam stop: |
- Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)
O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt
ns