PbF2 CrystalNumber39: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Oborn (talk | contribs)
Oborn (talk | contribs)
Line 80: Line 80:
@11:20 [[Image:Pulseb391120.JPG | 200 px]]
@11:20 [[Image:Pulseb391120.JPG | 200 px]]


 
@11:30 [[Image:Pulseb391120.JPG | 200 px]]
 






[http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back]
[http://iac.isu.edu/mediawiki/index.php/IAC_LeadFlourideCherenkovCrystalTests Go Back]

Revision as of 18:35, 5 December 2007

Below are the resulting transparency measurements for PbF2 block # 39

12/4/07

Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns)
beam start: 8:30
beam stop: 10:30
Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)

O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns

@8:53

@9:04

@9:17

@9:29

@9:45

@9:55

@10:16

Before: After:

Dose rate measurements (@1039 hours)
[math]\displaystyle{ \gamma }[/math]-radiation 7.5 mR/hr
[math]\displaystyle{ \beta }[/math]-radiation: 15 mR/hr


Transparency Measurements (@1400 hours)

Transparency Measurements (@1515 hours)

12/5/07

Accelerator Settings
beam energy 20 MeV
Rep Rate: 30 Hz
I_peak: 60 mA/pulse
pulse width: 0.1 [math]\displaystyle{ \mu }[/math]s (100 ns)
beam start: 10:45
beam stop:
Pick-up Coil Pulse Recording (PbF2 crystal at z=30cm away)

O-scope pulses were recorded on the pick-up coil with dimensions in inches and the intensity measured in Volt [math]\displaystyle{ \times }[/math] ns


@11:00

@11:10

@11:20

@11:30


Go Back