MVME6100> tftpGet -cCLIENT_IP_ADDRESS -sSERVER_IP_ADDRESS -fFILENAME | MVME6100> tftpGet -cCLIENT_IP_ADDRESS -sSERVER_IP_ADDRESS -fFILENAME | ||
− | CLIENT_IP_ADDESS is the IP address of the computer receiving the file | + | CLIENT_IP_ADDESS is the IP address of the computer receiving the file <br> |
− | SERVER_IP_ADDRESS is the IP address of the computer hosting the file (by default tftp uses the subdirectory /tftpboot) | + | SERVER_IP_ADDRESS is the IP address of the computer hosting the file (by default tftp uses the subdirectory /tftpboot) <br> |
+ | |||
+ | |||
+ | MVME6100> tftpGet -c134.50.3.216 -s134.50.3.210 -fboot6100_122.bin | ||
+ | Network Loading from: /dev/enet0 | ||
+ | Loading File: boot6100_122.bin | ||
+ | Load Address: 006B7000 | ||
+ | Download Buffer Size = 00200000 | ||
+ | |||
+ | Client IP Address = 134.50.3.216 | ||
+ | Server IP Address = 134.50.3.210 | ||
+ | Gateway IP Address = 134.50.3.253 | ||
+ | Subnet IP Address Mask = 255.255.255.0 | ||
+ | |||
+ | Network File Load in Progress... | ||
+ | |||
+ | Bytes Received =&594768, Bytes Loaded =&594768 | ||
+ | Bytes/Second =&594768, Elapsed Time =1 Second(s) | ||
=== Flash the RAM with the program=== | === Flash the RAM with the program=== |
Revision as of 20:30, 20 August 2007
MVME 6100
ROC1 ethernet address: 0001AF1998B5
ROC1 ethernet address: 0001AF1998B6
MPC7457 RISC G4 processor (PPC family)
Install tftp onto the Linux host computer
For CentOS I used yum
yum install tftp
yum install tftp-server
then I looked in the file
/etc/xinitd.d/tftp
- default: off
- description: The tftp server serves files using the trivial file transfer \
- protocol. The tftp protocol is often used to boot diskless \
- workstations, download configuration files to network-aware printers, \
- and to start the installation process for some operating systems.
service tftp
{
socket_type = dgram protocol = udp wait = yes user = root server = /usr/sbin/in.tftpd server_args = -s /tftpboot disable = yes per_source = 11 cps = 100 2 flags = IPv4
}
to see how tftp was configured by default. The file tell me that the tftp files should be located in the subdirectory
/tftpboot
turn the server on
/sbin/chkconfig tftp on
Download files from JLAB
I downloaded the boot file and VXworks kernel from JLAB
/site/coda/kern/5.5/boot/boot6100_122.bin /site/coda/kern/5.5/vx6100_v4.1
Debug Connector
I then used the serial port on the host computer to interface with the MVME6100 via the "DEBUG" port. The debug port took an RJ45 standard cable so I got and RJ45-DB9 converter. This seemed to work out of the box. Just in case I ever need to make my own connector record the pinouts below.
Information below is Table 5-11 pg 92 of this reference
ROC Pin# | DB9 Pin # | DB9 shell | Signal |
1 | 1 | Blue | DCD (Carrier Detect) |
2 | 7 | Orange | RTS (Request to Send) |
3 | 5 | Black | GNDC |
4 | 3 | Red | TX (Transmit) |
5 | 2 | Green | RX (Recieve) |
6 | 5 | Yellow | GNDC |
7 | 8 | Brown | CTS (Clear to Send) |
8 | 4 | White | DTR (Data Terminal Ready) |
Basic commands
setting the time
The command below will print the help screen for the time set command
he set
for example
MVME6100> set -t082604163100
MVME6100> time
THU AUG 26 16:31:02.00 2004
Ping another computer to check network
MVME6100> ping -c134.50.3.216 -s134.50.3.210 Client (Source) IP Address = 134.50.3.216 Server (Destination) IP Address = 134.50.3.210 Server/Host Found, E-Address = 0030487A9468 170 (128+42) bytes from 134.50.3.210: icmp_seq=0 time=179 us Packets Transmitted =1, Packets Received =1, Packets Lost =0 (0%) Round-Trip Min/Avg/Max = 179/179/179 uS
show the flash memory
MVME6100> flashShow
Load in the VxWorks boot kernel
MVME6100> tftpGet -cCLIENT_IP_ADDRESS -sSERVER_IP_ADDRESS -fFILENAME
CLIENT_IP_ADDESS is the IP address of the computer receiving the file
SERVER_IP_ADDRESS is the IP address of the computer hosting the file (by default tftp uses the subdirectory /tftpboot)
MVME6100> tftpGet -c134.50.3.216 -s134.50.3.210 -fboot6100_122.bin
Network Loading from: /dev/enet0
Loading File: boot6100_122.bin
Load Address: 006B7000
Download Buffer Size = 00200000
Client IP Address = 134.50.3.216 Server IP Address = 134.50.3.210 Gateway IP Address = 134.50.3.253 Subnet IP Address Mask = 255.255.255.0
Network File Load in Progress...
Bytes Received =&594768, Bytes Loaded =&594768 Bytes/Second =&594768, Elapsed Time =1 Second(s)
Flash the RAM with the program
>MVME6100>flashProgram -d/dev/flash0 -o03f00100 -nfff00
After flashing you flip dipswitch #2 on S4 fo off and powercycle