CaGaS Phase II: Difference between revisions
Jump to navigation
Jump to search
| Line 25: | Line 25: | ||
[[CH He3 Attenuation Measurements Revisited]] | [[CH He3 Attenuation Measurements Revisited]] | ||
[[CH He3 Attenuation Measurements | [[CH He3 Attenuation Measurements: 3 Different Cf252 Sources]] | ||
='''CaGaS Phase I Expansion'''= | ='''CaGaS Phase I Expansion'''= | ||
Revision as of 17:23, 9 June 2022
CaGaS Phase II Physical Parameters
Polyethylene
Radioactive Sources
Neutron Attenuation Measurements
Discriminator Dual Pulsing Investigation
Initial Measurements
CH He3 Attenuation Measurements
Revisited Measurements
CH He3 Attenuation Measurements Revisited
CH He3 Attenuation Measurements: 3 Different Cf252 Sources
CaGaS Phase I Expansion
Previous Work
Useful Resources
old old source data
Poly Box Attenuation Measurements
Open Source
| 1250V source in | |||||||
| Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) | Count Rate (Hz) | Uncertainty |
| 1 | Detector on poly at +1250V | 80 | Yes | 31 | 100 | ||
| 2 | Detector on poly at +1250V | 80 | Yes | 32 | 100 | ||
| 3 | Detector on poly at +1250V | 80 | Yes | 26 | 100 | ||
| 4 | Detector on poly at +1250V | 80 | Yes | 23 | 100 | ||
| 5 | Detector on poly at +1250V | 80 | Yes | 29 | 100 |
2" Green poly (one brick) in Box
| 1250V source in | |||||||
| Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) | Count Rate (Hz) | Uncertainty |
| 1 | Detector on poly at +1250V | 80 | Yes | 18 | 100 | ||
| 2 | Detector on poly at +1250V | 80 | Yes | 27 | 100 | ||
| 3 | Detector on poly at +1250V | 80 | Yes | 21 | 100 | ||
| 4 | Detector on poly at +1250V | 80 | Yes | 21 | 100 | ||
| 5 | Detector on poly at +1250V | 80 | Yes | 22 | 100 |
4" Green poly (two bricks) in Box
| 1250V source in | |||||||
| Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) | Count Rate (Hz) | Uncertainty |
| 1 | Detector on poly at +1250V | 80 | Yes | 31 | 100 | ||
| 2 | Detector on poly at +1250V | 80 | Yes | 18 | 100 | ||
| 3 | Detector on poly at +1250V | 80 | Yes | 19 | 100 | ||
| 4 | Detector on poly at +1250V | 80 | Yes | 31 | 100 | ||
| 5 | Detector on poly at +1250V | 80 | Yes | 30 | 100 |
6" Green poly (three bricks) in Box
| 1250V source in | |||||||
| Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) | Count Rate (Hz) | Uncertainty |
| 1 | Detector on poly at +1250V | 80 | Yes | 35 | 100 | ||
| 2 | Detector on poly at +1250V | 80 | Yes | 24 | 100 | ||
| 3 | Detector on poly at +1250V | 80 | Yes | 23 | 100 | ||
| 4 | Detector on poly at +1250V | 80 | Yes | 21 | 100 | ||
| 5 | Detector on poly at +1250V | 80 | Yes | 22 | 100 |
8" Green poly (four bricks) in Box
| 1250V source in | |||||||
| Run Number | Configuration | Discriminator Threshold (mV) | Cf-252 Source | Counts | Run Time (Sec) | Count Rate (Hz) | Uncertainty |
| 1 | Detector on poly at +1250V | 80 | Yes | 20 | 100 | ||
| 2 | Detector on poly at +1250V | 80 | Yes | 28 | 100 | ||
| 3 | Detector on poly at +1250V | 80 | Yes | 29 | 100 | ||
| 4 | Detector on poly at +1250V | 80 | Yes | 16 | 100 | ||
| 5 | Detector on poly at +1250V | 80 | Yes | 22 | 100 |