Difference between revisions of "PAS Feasibility Preliminary Runs"
Jump to navigation
Jump to search
Line 15: | Line 15: | ||
=='''7/19/21'''== | =='''7/19/21'''== | ||
− | NaI Detector, 5mV threshold, +1000V on detector | + | NaI Detector, 5mV threshold, +1000V on detector, no converter |
{| class="wikitable mw-collapsible mw-collapsed" border="2" style="text-align:center;" |cellpadding="20" cellspacing="1 | {| class="wikitable mw-collapsible mw-collapsed" border="2" style="text-align:center;" |cellpadding="20" cellspacing="1 | ||
! Source Distance from Intersection (cm) !! Counts !! Run Time (s) !! Count Rate (Hz) !! Uncertainty || | ! Source Distance from Intersection (cm) !! Counts !! Run Time (s) !! Count Rate (Hz) !! Uncertainty || | ||
|- | |- | ||
− | | 39.5 || || | + | | 39.5 || || 100 || || |
|- | |- | ||
− | | || || || || | + | | || || || 100 || || |
|- | |- | ||
− | | || || || || | + | | || || || 100 || || |
|} | |} | ||
+ | NaI Detector, 5mV threshold, +1000V on detector, with converter | ||
+ | {| class="wikitable mw-collapsible mw-collapsed" border="2" style="text-align:center;" |cellpadding="20" cellspacing="1 | ||
+ | ! Source Distance from Intersection (cm) !! Counts !! Run Time (s) !! Count Rate (Hz) !! Uncertainty || | ||
+ | |- | ||
+ | | 39.5 || || 100 || || | ||
+ | |- | ||
+ | | || || || 100 || || | ||
+ | |- | ||
+ | | || || || 100 || || | ||
+ | |} | ||
Revision as of 19:37, 19 July 2021
This experimental setup does not contain BorAl
General run plan
- Run source in and source out in experimental setup and background subtract with NaI
- Move the source to different locations along the source tunnel and plot the different distances and count rates
- Run source in and source out in experimental setup and background subtract with He3
- Move the source to different locations along the source tunnel and plot the different distances and count rates
I will upload some models of the setup when I have updated the model to include the source and detector
7/19/21
NaI Detector, 5mV threshold, +1000V on detector, no converter
Source Distance from Intersection (cm) | Counts | Run Time (s) | Count Rate (Hz) | Uncertainty | |
---|---|---|---|---|---|
39.5 | 100 | ||||
100 | |||||
100 |
NaI Detector, 5mV threshold, +1000V on detector, with converter
Source Distance from Intersection (cm) | Counts | Run Time (s) | Count Rate (Hz) | Uncertainty | |
---|---|---|---|---|---|
39.5 | 100 | ||||
100 | |||||
100 |