Difference between revisions of "Mlr Summ TF"
Line 82: | Line 82: | ||
=====Photons Hits in R1===== | =====Photons Hits in R1===== | ||
− | [[File:S1R1GammaHits_withTomography.png | | + | [[File:S1R1GammaHits_withTomography.png |800 px]] |
=====Secondary Electron Hits in R1===== | =====Secondary Electron Hits in R1===== |
Revision as of 17:32, 31 August 2018
VanWasshenova_Thesis#Mlr_Summ_TF
Moller Summary
Scattering Xsect
https://wiki.iac.isu.edu/index.php/Converting_to_barns
Weight the E-vs-Theta plot with Xsect
Baseline
Moller events using an lH2 target geometry No Raster
DC hits -vs- Solenoid
Starting the clas12 Moller simulation with a simple configuration, most components downstream with respect to the drift chambers are taken out of the gcard file. The remaining components, the Drift Chamber (DC), the Solenoid, and the Magnetic Components (CAD) are all that remain as shown below. The Torus field is held at zero Tesla, and the Solenoid field strength is increased from 0 to it's max of 5T.
As the Solenoid field strength increases, the Moller electrons are forced to into a helical path of decreasing radius, effectively "rotating" off the DC face. The relative value of the field changes the direction field, which in turn causes slightly more hits to be deposited on one side versus the other. This effect is only noticeable in that the neighboring sectors to S1 were not simulated.
However, as the field reaches maximum, there are still particles which are found at higher values of
that would have been expected to have remained after the effects of the Solenoid. To understand the causes of this phenomena, the hits on Region 1 can be broken into the most common types of particles that are detected; Primary Moller electrons and secondary electrons and photons caused by the Moller electron. Looking more closely at this particle makeup as the solenoid field is increased, we can see that the ratio of primary electrons to total hits decreases while the ratio of photons to total hits increases.
Without Magnet Components
To examine the possibility that scattering is the cause of the noise, the simulation is further simplified by removing the magnetic components stored in the CAD directory.
To effectively determine the cause of the remaining particles in S1R1 the hit particles' vertex points can be recorded producing a tomography plot. A changing field is still useful in that the lack of number of hits at high solenoid field strength would make determining the physical cause difficult.
Photons Hits in R1
Secondary Electron Hits in R1
Primary Moller Electron Hits in R1
Moller events using an dual polarized target geometry with Raster
Photon Hits in R1 when Raster size has radius of 0.2 cm
Moller rate -vs- length of a single taerget
0.5 cm radius -vs- Z
Target is a one 0.5 cm radius cylinder of length Z.
By how much does the moller rate change at full field ?