Difference between revisions of "NAA SolarPanel"
Line 24: | Line 24: | ||
− | In File name: | + | ==In File name: |
− | 10uC_Cs_Mn_SolarPan_DetD_55.5cm_002.mpa | + | 10uC_Cs_Mn_SolarPan_DetD_55.5cm_002.mpa== |
Measurements started at 14:45:38, 2:38:08 (158 min, 9488 sec) after irradiation ended, | Measurements started at 14:45:38, 2:38:08 (158 min, 9488 sec) after irradiation ended, | ||
Line 62: | Line 62: | ||
|4000 || Solar Panel A 15 cm away from face (2 % deadtime, 880 Hz DAQ rate) | |4000 || Solar Panel A 15 cm away from face (2 % deadtime, 880 Hz DAQ rate) | ||
+ | |} | ||
+ | ==In File name: | ||
+ | 10uC_Cs_Mn_SolarPan_DetD_55.5cm_003.mpa== | ||
+ | |||
+ | Measurements started at 14:45:38, 2:38:08 (158 min, 9488 sec) after irradiation ended, | ||
+ | |||
+ | Add 9488 seconds to time below to get time since irradiation | ||
+ | |||
+ | {| border="1" |cellpadding="20" cellspacing="0 | ||
+ | | Category|| Cost | ||
+ | |- | ||
+ | |Time (sec) || Sample | ||
+ | |- | ||
+ | |0 || Thorium Rods on face of detector | ||
+ | |- | ||
+ | |300 || Mn sample (847 keV) 55.5 cm away from face | ||
+ | |- | ||
|} | |} | ||
Revision as of 22:25, 23 May 2018
Irradiated on Jack by placing samples just above the Radiator as shown in the picture.
Beam parameters: Irradiation Date : 5/23/18
Start Time: 09:07:30
Stop Time: 11:07:30
Rep Rate=300 Hz
I = 98 mA
Pulse Width = 10 usec
E = 38 MeV
The solar panel current output dropped 1 mA per hour during irradiation. The cove was too dark to produce a signal from ambient light. The observed signal was completely due to the electron beam.
==In File name:
10uC_Cs_Mn_SolarPan_DetD_55.5cm_002.mpa==
Measurements started at 14:45:38, 2:38:08 (158 min, 9488 sec) after irradiation ended,
Add 9488 seconds to time below to get time since irradiation
Category | Cost |
Time (sec) | Sample |
0 | Cs-137 (661 keV line) #64121 55.5 cm away from face |
360 | Mn sample (1.7 g, 1.5 cm x 1.5 cm square, 847 keV) 55.5 cm away from face |
690 | Thorium Rods on face of detector |
1020 | Solar Panel A 55.5 cm away from face |
1410 | Cs-137 #129792 55.5 cm away from face |
1820 | Mn sample (847 keV) 55.5 cm away from face |
2230 | Cs-137 #129792 55.5 cm away from face (0.54% deadtime) |
2560 | Solar Panel A 55.5 cm away from face (0.55% deadtime, 300 Hz DAQ rate) |
2880 | Cs-137 (661 keV line) #64121 55.5 cm away from face (1.1% deadtime, 350 Hz) |
3070 | Mn sample (847 keV) 55.5 cm away from face (13 % deadtime, 4600 Hz) |
3330 | Ignore (Mn source was too close) Cs-137 #129792 15 cm away from face(6 % deadtime, 2000 Hz) |
3600 | Cs-137 #129792 15 cm away from face(.5 % deadtime, 200 Hz) |
4000 | Solar Panel A 15 cm away from face (2 % deadtime, 880 Hz DAQ rate) |
==In File name: 10uC_Cs_Mn_SolarPan_DetD_55.5cm_003.mpa==
Measurements started at 14:45:38, 2:38:08 (158 min, 9488 sec) after irradiation ended,
Add 9488 seconds to time below to get time since irradiation
Category | Cost |
Time (sec) | Sample |
0 | Thorium Rods on face of detector |
300 | Mn sample (847 keV) 55.5 cm away from face |