LB Feb Nickel Consistency Check: Difference between revisions

From New IAC Wiki
Jump to navigation Jump to search
Brenleyt (talk | contribs)
No edit summary
Brenleyt (talk | contribs)
No edit summary
Line 44: Line 44:
||Background Subtracted Signal || 230.89 +/- 7.36
||Background Subtracted Signal || 230.89 +/- 7.36
|-
|-
||.dat file entry ||5.441941407 +/- 0.0318766512
|}
 
 
Since the efficiency is unknown I will plot the ratio of the activities so the efficiency cancels out. Below is a table of rations that will be entered into a .dat File
 
{| border="3"  cellpadding="5" cellspacing="0"
|| 2/14/17 (r5924) || 2/15/17 (r5932) ||
|-
||1.135822511 +/- 0.059600344
|-
|-
|}
|}

Revision as of 18:29, 8 November 2017

This analysis was done on Inv # 170010 which was irradiated in February 2017 with a rotating sample holder. This was a 50% mix of Se and Soil. The mass of the front nickel foil was 0.27 grams and the mass of the rear nickel foil was 0.25 grams. The histograms made were weighted by the time of the run and the mass of the nickel foil.


Below is a table for the front nickel foil:

2/14/17 (r5923) 2/15/17 (r5931)
Original Window
Expanded Window
Original Background 0.0.6227 +/- 0.1145 0.659037 +/- 0.114807
Expanded Background 0.2953 +/- 0.0645 0.370149 +/- 0.0727176
Signal Background (Take Larger Error) 0.6227 +/- 0.1145 0.659037 +/- 0.114807
Signal in Window (Hz) 203.9 +/- 12.14
Background Subtracted Signal 203.28 +/- 12.14


Below is a table for the rear nickel foil:

2/14/17 (r5924) 2/15/17 (r5932)
Original Window
Expanded Window
Original Background 0.712245 +/- 0.119352
Expanded Background 0.366691 +/- 0.0723771
Signal Background (Take Larger Error) 0.712245 +/- 0.119352
Signal in Window (Hz) 231.6 +/- 7.356
Background Subtracted Signal 230.89 +/- 7.36


Since the efficiency is unknown I will plot the ratio of the activities so the efficiency cancels out. Below is a table of rations that will be entered into a .dat File

2/14/17 (r5924) 2/15/17 (r5932)
1.135822511 +/- 0.059600344